Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,197,124Inspections Most recent open 2026-08-25 Last loaded 2026-08-28

OSHA Inspection: BULL MOOSE TUBE CO.

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of BULL MOOSE TUBE CO. in 195 N. INDUSTRIAL BOULEVARD, TRENTON, GA 30752 (NAICS 331210). OSHA activity number 339814758.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Bull Moose Tube CO. for free Get an email when a new federal OSHA severe-injury report for Bull Moose Tube CO. is published. One employer, no account, unsubscribe in one click.
Establishment
BULL MOOSE TUBE CO.
Site address
195 N. INDUSTRIAL BOULEVARD
City
TRENTON
State
GA
ZIP
30752
Mailing
P.O. BOX 511, TRENTON, GA 30752
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
Union (A)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
331210
Employees
47
Ownership type
Private (A)

3 citations on file for this inspection.

1910.179 L03 III D

Other-than-serious 1 instance 3 exposed
Issued
Sep 5, 2014
Penalty
Initial $2,100 · Current $0 Reduced
29 CFR 1910.179(l)(3)(iii)(d): Pendant control stations were not kept clean, and/or their function labels were not kept legible:    a) Mill 1: The employer did not ensure that function labels on the pendant controlling the 5-ton Konecrane (CXT) jib crane were legible.
Recent events (2)
  • · I (O) $0
  • · Z (S) $2100

1910.305 B02 I

Other-than-serious 1 instance 2 exposed
Issued
Sep 5, 2014
Penalty
Initial $2,100 · Current $2,100
29 CFR 1910.305(b)(2)(i): Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose:    a) Slitting Area: The employer failed to ensure that a junction box at the slitter uncoiler  (Parker Model D3W1CNYG) was provided with a cover to prevent the interior wires from exposing employees working in the area to shock hazards.
Recent events (2)
  • · I (O) $2100
  • · Z (S) $2100

1910.1200 H01

Other-than-serious 1 instance 47 exposed
Issued
Sep 5, 2014
Abate by
Oct 1, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area:  a) Mill and Slitting Areas: Employees were required to work with chemicals such as, but not limited to Carbon and Low Alloy Steel, Hot Rolled Alloy Steel Sheet, TAFA Tin Alloy Wire, Tube-Alloy Cobalt Based Cored Wires, and Welding gases while forming steel tubes.  The employer did not provide training specific to the hazards of chemical used at the establishment to all employees working with hazardous chemicals.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

View Bull Moose Tube CO.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339814758.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.