LITTLETON, CO —
OSHA Inspection: ECO TECH ENVIRONMENTAL, INC.
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of ECO TECH ENVIRONMENTAL, INC. in 24 CLUB LANE, LITTLETON, CO 80123 (NAICS 562910). OSHA activity number 339820540.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ECO TECH ENVIRONMENTAL, INC.
- Site address
- 24 CLUB LANE
- City
- LITTLETON
- State
- CO
- ZIP
- 80123
- Mailing
- 2331 W. HAMPDEN AVENUE SUITE 137, SHERIDAN, CO 80110
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 562910
- Employees
- 5
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.1101 H03 IV A
- Issued
- Jul 11, 2014
- Abate by
- Jul 17, 2014
- Penalty
- Initial $1,020 · Current $1,020
General-duty citation text
29 CFR 1926.1101(h)(3)(iv)(A): A tight-fitting powered air-purifying respirator or a full facepiece, supplied-air respirator operated in the pressure-demand mode and equipped with either HEPA egress cartridges or an auxiliary positive-pressure, self-contained breathing apparatus (SCBA) was not provided to employees in a regulated area performing Class I asbestos work for which a negative exposure assessment was not available and the exposure assessment indicated that the exposure level will be at or below 1 f/cc as an 8-hour time-weighted average (TWA): a) On or about June 24, 2014, and at times prior, the employer did not provide employees performing Class I asbestos abatement work inside of a regulated area (containment area) with a full-face powered air-purifying respirator or a supplied air respirator. Employees were performing removal of drywall and ceiling which was covered by asbestos containing surfacing material while wearing half-face air-purifying respirators. A negative exposure assessment had not been conducted for these employees and was not used as the basis for respirator selection.
Recent events (2)
- — I (O) $1020
- — Z (S) $1020
1910.134 F02
- Issued
- Jul 11, 2014
- Abate by
- Jul 17, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(f)(2): The employer shall ensure that an employee using a tight-fitting facepiece respirator is fit tested prior to initial use of the respirator, whenever a different respirator facepiece (size, style, model or make) is used, and at least annually thereafter: a) On or about June 24, 2014, and at times prior, Eco Tech Environmental, Inc., as the controlling employer, did not ensure that employees of Imperial M&B were fully protected from asbestos exposure because Eco Tech allowed the employees to perform abatement work using full-face respirators which had not been fit tested.
Recent events (2)
- — I (O) $0
- — Z (S) $0
More inspections at ECO Tech Environmental, INC.
View ECO Tech Environmental, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 562910)
More inspections in CO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339820540.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.