OSHA Inspection: U.S. DEPT. OF AGRICULTURE FOREST SERVICE - ANGELES NATIONAL FOREST

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of U.S. DEPT. OF AGRICULTURE FOREST SERVICE - ANGELES NATIONAL FOREST in SAN GABRIEL RANGER STATION 110 N. WABASH AVE., GLENDORA, CA 91741 (NAICS 924120). OSHA activity number 339821373.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch U.S. Dept. of Agriculture Forest Service - Angeles National Forest for free Get an email when a new federal OSHA severe-injury report for U.S. Dept. of Agriculture Forest Service - Angeles National Forest is published. One employer, no account, unsubscribe in one click.
Site address
SAN GABRIEL RANGER STATION 110 N. WABASH AVE.
City
GLENDORA
State
CA
ZIP
91741
Mailing
701 N. SANTA ANITA AVE, ARCADIA, CA 91006
Inspection type
Unprogrammed Other (J)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Union (A)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
924120
Employees
15
Ownership type
Federal government (D)

4 citations on file for this inspection.

1910.305 G01 IV

Serious Gravity 1 3 instances 15 exposed
Issued
Sep 25, 2014
Abate by
Oct 7, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv): Flexible cords and/ or cables were used for purposes prohibited by paragraphs (A) through (F) of 29 CFR 1910.305(g)(1)(iv):  (a) Kitchen: A flexible cord providing 120VAc service to a microwave oven was run through a hole in the wall of the cabinet.  (b) Kitchen: A flexible cord providing 120VAc service to a television was attached to the wall surface.  (c) Library: The flexible cord of a power strip was attached to the wall surface.
Recent events (1)
  • · Z (S) $0

1910.157 E02

Repeat Gravity 1 2 instances 15 exposed
Issued
Sep 25, 2014
Abate by
Oct 7, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.157(e)(2): Portable fire extinguishers were not visually inspected at least monthly:  (a) Reception: A fire extinguisher was last visually inspected October, 2013.  (b) Hallway: A fire extinguisher was last visually inspected October, 2013.  The USDA Forest Service was previously cited for a repeat violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.157(e)(2), which was contained in OSHA inspection number 957451, citation number 2, item number 3, and was affirmed as a final order on April 7, 2014, with respect to a workplace located at 1634 Black Canyon Rd., Goose Valley Fire Station, Ramona, CA 92065    The USDA Forest Service was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.157(e)(2), which was contained in OSHA inspection number 910625, citation number 1, item number 2, and was affirmed as a final order on July 29, 2013 with respect to a workplace located at 602 S. Tippecanoe Ave., San Bernardino, CA 92408.
Recent events (1)
  • · Z (R) $0

1910.303 B02

Repeat Gravity 1 4 instances 15 exposed
Issued
Sep 25, 2014
Abate by
Oct 7, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:  (a) Kitchen: A power strip was used to provide 120VAC electrical service for two microwaves.  (b) Kitchen: A television was provided 120VAC service by an extension cord plugged into a power strip.  (c) Battalion 23 office: A power strip was used to provide 120VAC electrical service to a refrigerator.  (d) Reception: two power strips were plugged into another power strip to provide 120 VAC to the receptionist desk.   The USDA Forest Service was previously cited for a repeat violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.303(b)(2), which was contained in OSHA inspection number 957451, citation number 2, item number 5, and was affirmed as a final order on April 7, 2014, with respect to a workplace located at 1634 Black Canyon Rd., Goose Valley Fire Station, Ramona, CA 92065    The USDA Forest Service was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.303(b)(2), which was contained in OSHA inspection number 911912, citation number 1, item number 8, and was affirmed as a final order on August 6, 2013, with respect to a workplace located at 28500 Highway 243, Keenwild Station, Mountain Center, CA 92561.
Recent events (1)
  • · Z (R) $0

1910.303 B07 I

Repeat Gravity 1 1 instance 15 exposed
Issued
Sep 25, 2014
Abate by
Oct 22, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.303(b)(7)(i): Unused openings in boxes, raceways, auxiliary gutters, cabinets, equipment cases, or housings were not effectively closed to afford protection substantially equivalent to the wall of the equipment:  Library: Two openings on the surface of an electrical cabinet were not effectively closed where a snap switch was removed, and attachment screw was missing.   The USDA Forest Service was previously cited for a repeat violation of this occupational safety and health standard or its equivalent standard 29 CFR 10.303(b)(7)(i), which was contained in OSHA inspection number 957451, citation number 2, item number 3, and was affirmed as a final order on April 11, 2014, with respect to a workplace located at 32353 Ortega Highway, Lake Elsinore, CA 92530.    The USDA Forest Service was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.303(b)(7)(i), which was contained in OSHA inspection number 911912, citation number 1, item number 9, and was affirmed as a final order on August 6, 2013, with respect to a workplace located at 28500 Highway 243, Keenwild Station, Mountain Center, CA 92561.
Recent events (1)
  • · Z (R) $0