OSHA Inspection: COMPLETE BUILDING MAINTENANCE CO.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of COMPLETE BUILDING MAINTENANCE CO. in 5304 HILLTOP ROAD, LONG GROVE, IL 60047 (NAICS 238160). OSHA activity number 339822785.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Complete Building Maintenance CO. — free Get an email when a new federal OSHA severe-injury report for Complete Building Maintenance CO. is published. One employer, no account, unsubscribe in one click.
Site address
5304 HILLTOP ROAD
City
LONG GROVE
State
IL
ZIP
60047
Mailing
702 WESTERN AVE., LOMBARD, IL 60148
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
6
Ownership type
A

5 citations on file for this inspection.

1926.501 B04 I

Serious Gravity 5 1 instance 6 exposed
Issued
Jul 9, 2014
Abate by
Jul 15, 2014
Penalty
Initial $3,500 · Current $1,750 Reduced
29 CFR 1926.501(b)(4)(i):  Each employee on walking/working surfaces was not protected from falling through holes (including skylights) more than 6 feet (1.8 m) above lower levels by personal fall arrest systems, covers or guardrail systems erected around such holes:        a) Employees were exposed to the hazard of falling approximately 18 feet through an unprotected skylight dome located in the roof deck work area.       In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (S) $1750
  • — Z (S) $3500

1926.501 B10

Serious Gravity 10 3 instances 3 exposed
Issued
Jul 9, 2014
Penalty
Initial $4,900 · Current $2,450 Reduced
29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs with unprotected sides and edges 6 feet or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system.  Or, on roofs 50-feet (15.25 m) or less in width, each employee was not protected by use of a monitoring system:      a) Employees were exposed to the hazard of falling approximately 18 feet from the edge of the roof deck while engaged in roofing activities without the use of fall protection or a safety monitor.     No abatement certification or documentation required for this violation.
Recent events (2)
  • — I (S) $2450
  • — Z (S) $4900

1926.502 I03

Serious Gravity 5 1 instance 6 exposed
Issued
Jul 9, 2014
Abate by
Jul 15, 2014
Penalty
Initial $3,500 · Current $1,750 Reduced
29 CFR 1926.502(i)(3): All covers were not secured when installed so as to prevent accidental displacement by the wind, equipment, or employees:         a) Employees were exposed to the hazard of falling approximately 18 feet where a cover over a skylight hole in the roof deck was not secured to prevent accidental displacement.     In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (S) $1750
  • — Z (S) $3500

1926.502 J04

Serious Gravity 5 1 instance 6 exposed
Issued
Jul 9, 2014
Abate by
Jul 15, 2014
Penalty
Initial $0 · Current $0
29 CFR 1926.502(i)(4): All covers were not color coded or marked with the word "HOLE" or "COVER" to provide warning of the hazard:        a) A cover over a skylight hole on the roof deck was not color coded or marked with the word "hole" or "cover" to provide warning of the hazard.     In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.1051 A

Serious Gravity 1 1 instance 6 exposed
Issued
Jul 9, 2014
Abate by
Jul 15, 2014
Penalty
Initial $2,100 · Current $1,050 Reduced
29 CFR 1926.1051(a): Stairway(s) or ladder(s) were not provided at all personnel points of access where there was a break in elevation of 19 inches (48 cm) or more, or no ramp, runway, sloped embankment, or personnel hoist was provided:       a) Employees were required to climb between two roof decks having a break in elevation of about 3 feet without a stairway or ladder provided for safe access and egress between the decks.      In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (S) $1050
  • — Z (S) $2100

View Complete Building Maintenance CO.'s full OSHA safety record →