SAINT PETERSBURG, FL —
OSHA Inspection: PENHAGLION, INC.
Unprogrammed Related inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Related safety inspection of PENHAGLION, INC. in 5843 CARRIER STREET N, SAINT PETERSBURG, FL 33714 (NAICS 332999). OSHA activity number 339823452.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PENHAGLION, INC.
- Site address
- 5843 CARRIER STREET N
- City
- SAINT PETERSBURG
- State
- FL
- ZIP
- 33714
- Mailing
- 5843 CARRIER STREET N, SAINT PETERSBURG, FL 33714
What kind of inspection was it?
- Inspection type
- Unprogrammed Related (G)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332999
- Employees
- 5
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.107 C06
- Issued
- Jun 30, 2014
- Abate by
- Jul 9, 2014
- Penalty
- Initial $1,200 · Current $720 Reduced
General-duty citation text
29 CFR 1910.107(c)(6): Electrical wiring and equipment not subject to deposits of combustible residues but located in a spraying area as herein defined were not explosion-proof type approved for Class I, group D locations and did not otherwise conform to the provisions of subpart S of this part, for Class I, Division 1, Hazardous Locations: (a) spray paint room - a portable cord/plug Timex radio was inside the spray paint room; observed on or about 5/7/14. (b) spray paint room - three cord/plug floor fans used for ventilation were inside the spray paint room; observed on or about 5/7/14. (c) spray paint room - a Defiant surge protector used to supply electricity to items including, but not limited to, a radio and floor fans was inside the spray paint room; observed on or about 5/7/14.
Recent events (2)
- — I (S) $720
- — Z (S) $1200
1910.107 C07
- Issued
- Jun 30, 2014
- Abate by
- Jul 9, 2014
- Penalty
- Initial $1,200 · Current $720 Reduced
General-duty citation text
29 CFR 1910.107(c)(7): Electric lamps outside of, but within 20 feet of spraying area(s), and not separated therefrom by partition(s), were not totally enclosed to prevent the falling of hot particles: (a) spray paint room - there were four uncovered fluorescent light bulbs on the ceiling; observed on or about 5/7/14.
Recent events (2)
- — I (S) $720
- — Z (S) $1200
1910.157 E03
- Issued
- Jun 30, 2014
- Abate by
- Jul 11, 2014
- Penalty
- Initial $1,200 · Current $720 Reduced
General-duty citation text
29 CFR 1910.157(e)(3): Portable fire extinguishers were not subjected to an annual maintenance check: (a) spray paint room - the fire extinguisher received its last maintenance check in June 2011; observed on or about 5/7/14.
Recent events (2)
- — I (S) $720
- — Z (S) $1200
1910.1200 E01
- Issued
- Jun 30, 2014
- Abate by
- Jul 25, 2014
- Penalty
- Initial $1,200 · Current $720 Reduced
General-duty citation text
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which described how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: (a) at the workplace - there was not a written hazard communication program where employees were exposed to chemicals used in the painting process including, but not limited to, Defleet Essential single-stage enamel, paint thinners, Triangle Coatings metallic surfacer, and Sophisticated Finishes metallic surfacer; observed on or about 5/7/14.
Recent events (2)
- — I (S) $720
- — Z (S) $1200
1910.1200 G08
- Issued
- Jun 30, 2014
- Abate by
- Jul 9, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(g)(8): The employer did not maintain in the workplace copies of the required safety data sheets for each hazardous chemical, and did not ensure that they were readily accessible during each work shift to employees when they were in their work area(s): (a) at the workplace - safety data sheets were not available for all the chemicals used at the workplace including, but not limited to, paint thinners, aging compounds, and metallic surfacers; observed on or about 5/7/14.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Penhaglion, INC.
View Penhaglion, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 332999)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339823452.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.