SAINT PETERSBURG, FL —
OSHA Inspection: PENHAGLION, INC.
Referral inspection · Health discipline
At a glance
On , OSHA opened a referral health inspection of PENHAGLION, INC. in 5843 CARRIER STREET N, SAINT PETERSBURG, FL 33714 (NAICS 332999). OSHA activity number 339999336.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PENHAGLION, INC.
- Site address
- 5843 CARRIER STREET N
- City
- SAINT PETERSBURG
- State
- FL
- ZIP
- 33714
- Mailing
- 5843 CARRIER STREET N, SAINT PETERSBURG, FL 33714
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332999
- Employees
- 5
- Ownership type
- A
Citations
9 citations on file for this inspection.
1910.94 C04 I
- Issued
- Oct 22, 2014
- Abate by
- Dec 10, 2014
- Penalty
- Initial $1,760 · Current $880 Reduced
General-duty citation text
29 CFR 1910.94(c)(4)(i): The spray room, including floors, was not constructed of masonry, concrete, or other noncombustible material: a) Spray Room - There was a wood ceiling, wood walls and a built-in wood work bench in the room, on or about October 10, 2014.
Recent events (2)
- — I (S) $880
- — Z (S) $1760
1910.94 C04 II
- Issued
- Oct 22, 2014
- Abate by
- Dec 10, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.94(c)(4)(ii): Spray rooms had combustible fire doors or shutters: a) Spray Room - There were two wood filter doors from the spray room into the main building, on or about October 10, 2014.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.107 D02
- Issued
- Oct 22, 2014
- Abate by
- Dec 10, 2014
- Penalty
- Initial $1,760 · Current $880 Reduced
General-duty citation text
29 CFR 1910.107(d)(2): Spraying areas were not provided with adequate mechanical ventilation to remove flammable vapors, mists, or powders to a safe location and to confine and control combustible residues so that life was not endangered: a) Spray Room - Airflow in the vicinity of the sprayed piece was 20 to 30 feet per minute, on or about October 10, 2014.
Recent events (2)
- — I (S) $880
- — Z (S) $1760
1910.107 E02
- Issued
- Oct 22, 2014
- Abate by
- Nov 18, 2014
- Penalty
- Initial $1,760 · Current $880 Reduced
General-duty citation text
29 CFR 1910.107(e)(2): The quantity of flammable or combustible liquids kept in the vicinity of spraying operations were not at a minimum required for operations or they exceeded a supply for one day or one shift: a) Spray Room - There was a three-quarters full 55 gallon drum of flammable solvents stored in the room, on or about October 10, 2014.
Recent events (2)
- — I (S) $880
- — Z (S) $1760
1910.107 C06
- Issued
- Oct 22, 2014
- Abate by
- Dec 10, 2014
- Penalty
- Initial $3,520 · Current $1,760 Reduced
General-duty citation text
29 CFR 1910.107(c)(6): Electrical wiring and equipment not subject to deposits of combustible residues but located in a spraying area as herein defined were not explosion-proof type approved for Class I, group D locations and did not otherwise conform to the provisions of subpart S of this part, for Class I, Division 1, Hazardous Locations: a) Spray Room - There were 120 volt AC outlets, fluorescent lighting, snap switches, junction boxes and two electric fans in use, on or about October 10, 2014. Penhaglion, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1910.107(c)(6), which was contained in OSHA inspection number 982345, citation number 1, item number 1 and was affirmed as a final order on July 15, 2014, with respect to a workplace located at 5843 Carrier St. N, St. Petersburg, FL.
Recent events (2)
- — I (R) $1760
- — Z (R) $3520
1910.134 C01
- Issued
- Oct 22, 2014
- Abate by
- Nov 26, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use: a) Spray Room - No respirator program was developed, on or about October 10, 2014.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.134 E01
- Issued
- Oct 22, 2014
- Abate by
- Nov 26, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: a) Spray Room - No medical evaluations were provided, on or about October 10, 2014.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.134 F01
- Issued
- Oct 22, 2014
- Abate by
- Nov 26, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(f)(1): The employer did not ensure that employee(s) required to use a tight-fitting facepiece respirator passed the appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT): a) Spray Room - No fit tests were provided, on or about October 10, 2014.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.134 G01 I A
- Issued
- Oct 22, 2014
- Abate by
- Nov 26, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(g)(1)(i)(A): Respirators with tight-fitting facepieces were worn by employees who had facial hair that came between the sealing surface of the facepiece and the face or that interfered with valve function: a) Spray Room - The spray painter had a beard, on or about October 10, 2014.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Penhaglion, INC.
View Penhaglion, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 332999)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339999336.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.