Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: PENHAGLION, INC.

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of PENHAGLION, INC. in 5843 CARRIER STREET N, SAINT PETERSBURG, FL 33714 (NAICS 332999). OSHA activity number 339999336.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Penhaglion, INC. — free Get an email when a new federal OSHA severe-injury report for Penhaglion, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
PENHAGLION, INC.
Site address
5843 CARRIER STREET N
City
SAINT PETERSBURG
State
FL
ZIP
33714
Mailing
5843 CARRIER STREET N, SAINT PETERSBURG, FL 33714
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332999
Employees
5
Ownership type
A

9 citations on file for this inspection.

1910.94 C04 I

Serious Gravity 5 1 instance 2 exposed
Issued
Oct 22, 2014
Abate by
Dec 10, 2014
Penalty
Initial $1,760 · Current $880 Reduced
29 CFR 1910.94(c)(4)(i): The spray room, including floors, was not constructed of masonry, concrete, or other noncombustible material:     a)  Spray Room - There was a wood ceiling, wood walls and a built-in wood work bench in the room, on or about October 10, 2014.
Recent events (2)
  • — I (S) $880
  • — Z (S) $1760

1910.94 C04 II

Serious Gravity 5 1 instance 2 exposed
Issued
Oct 22, 2014
Abate by
Dec 10, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.94(c)(4)(ii): Spray rooms had combustible fire doors or shutters:   a)  Spray Room - There were two wood filter doors from the spray room into the main building, on or about October 10, 2014.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.107 D02

Serious Gravity 5 1 instance 2 exposed
Issued
Oct 22, 2014
Abate by
Dec 10, 2014
Penalty
Initial $1,760 · Current $880 Reduced
29 CFR 1910.107(d)(2): Spraying areas were not provided with adequate mechanical ventilation to remove flammable vapors, mists, or powders to a safe location and to confine and control combustible residues so that life was not endangered:      a)  Spray Room - Airflow in the vicinity of the sprayed piece was 20 to 30 feet per minute, on or about October 10, 2014.
Recent events (2)
  • — I (S) $880
  • — Z (S) $1760

1910.107 E02

Serious Gravity 5 1 instance 2 exposed
Issued
Oct 22, 2014
Abate by
Nov 18, 2014
Penalty
Initial $1,760 · Current $880 Reduced
29 CFR 1910.107(e)(2): The quantity of flammable or combustible liquids kept in the vicinity of spraying operations were not at a minimum required for operations or they exceeded a supply for one day or one shift:      a)  Spray Room - There was a three-quarters full 55 gallon drum of flammable solvents stored in the room, on or about October 10, 2014.
Recent events (2)
  • — I (S) $880
  • — Z (S) $1760

1910.107 C06

Repeat Gravity 5 1 instance 2 exposed
Issued
Oct 22, 2014
Abate by
Dec 10, 2014
Penalty
Initial $3,520 · Current $1,760 Reduced
29 CFR 1910.107(c)(6): Electrical wiring and equipment not subject to deposits of combustible residues but located in a spraying area as herein defined were not explosion-proof type approved for     Class I, group D locations and did not otherwise conform to the provisions of subpart S of this part, for Class I, Division 1, Hazardous Locations:      a)  Spray Room - There were 120 volt AC outlets, fluorescent lighting, snap switches, junction boxes and two electric fans in use, on or about October 10, 2014.    Penhaglion, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1910.107(c)(6), which was contained in OSHA inspection number 982345, citation number 1, item number 1 and was affirmed as a final order on July 15, 2014, with respect to a workplace located at 5843 Carrier St. N, St. Petersburg, FL.
Recent events (2)
  • — I (R) $1760
  • — Z (R) $3520

1910.134 C01

Other-than-serious 1 instance 2 exposed
Issued
Oct 22, 2014
Abate by
Nov 26, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use:   a)  Spray Room - No respirator program was developed, on or about October 10, 2014.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.134 E01

Other-than-serious 1 instance 2 exposed
Issued
Oct 22, 2014
Abate by
Nov 26, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace:   a)  Spray Room - No medical evaluations were provided, on or about October 10, 2014.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.134 F01

Other-than-serious 1 instance 2 exposed
Issued
Oct 22, 2014
Abate by
Nov 26, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.134(f)(1): The employer did not ensure that employee(s) required to use a tight-fitting facepiece respirator passed the appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT):   a)  Spray Room - No fit tests were provided, on or about October 10, 2014.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.134 G01 I A

Other-than-serious 1 instance 2 exposed
Issued
Oct 22, 2014
Abate by
Nov 26, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.134(g)(1)(i)(A): Respirators with tight-fitting facepieces were worn by employees who had facial hair that came between the sealing surface of the facepiece and the face or that interfered with valve function:   a)  Spray Room - The spray painter had a beard, on or about October 10, 2014.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Penhaglion, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339999336.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.