OSHA Inspection: SIDING SOURCE, LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of SIDING SOURCE, LLC in BUILDING 40 MONROE MANOR FORT LEE, FORT LEE, VA 23801 (NAICS 444110). OSHA activity number 339828527.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Siding Source, LLC — free Get an email when a new federal OSHA severe-injury report for Siding Source, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
SIDING SOURCE, LLC
Site address
BUILDING 40 MONROE MANOR FORT LEE
City
FORT LEE
State
VA
ZIP
23801
Mailing
PO BOX 143353, FAYETTEVILLE, GA 30214
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
444110
Employees
8
Ownership type
A

3 citations on file for this inspection.

1926.404 B01 II

Serious Gravity 5 1 instance 3 exposed
Issued
Jul 16, 2014
Abate by
Aug 5, 2014
Penalty
Initial $1,600 · Current $1,200 Reduced
29 CFR 1926.404(b)(1)(ii): Receptacles on a three-wire, dual voltage 120v/240v portable or vehicle-mounted generator rated at 5kW or more, where the circuit conductors of the generator are insulated from the generator frame and all other grounded surfaces, were not be protected with ground-fault circuit interrupters.  a.)  Siding Source, LLC., Fort Lee, Monroe Manor:  On or about 06/24/14, the receptacles on the Generac GP5500 portable generator were not GFCI protected.   Abatement certification required within 10 days after abatement date.  The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $1600

1926.501 B13

Serious Gravity 5 1 instance 1 exposed
Issued
Jul 16, 2014
Abate by
Aug 5, 2014
Penalty
Initial $2,000 · Current $1,500 Reduced
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):   a.)  Siding Source, LLC., Fort Lee, Monroe Manor:  On or about 06/24/14, an employee was observed working on a residential roof 24' above the ground without the use of a fall protection system.  Abatement certification required within 10 days after abatement date.  The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $1500
  • — Z (S) $2000

1910.1200 H03 IV

Other-than-serious 1 instance 3 exposed
Issued
Jul 16, 2014
Abate by
Aug 20, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(h)(3)(iv) as referenced by 29 CFR 1926.59: Employee training did not include the details of the hazard communication program developed by the employer, including an explanation of the labeling system and the material safety data sheet, and how employees can obtain and use the appropriate hazard information:   a.)  Siding Source, LLC., Fort Lee, Monroe Manor:  On or about 06/24/14, the employer had not trained their employees in the new labeling requirements and SDS format under Global Harmonization.  Abatement certification required within 10 days after abatement date.  The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.