SAEGERTOWN, PA —
OSHA Inspection: LORD CORPORATION
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of LORD CORPORATION in 601 SOUTH STREET, SAEGERTOWN, PA 16433 (NAICS 325510). OSHA activity number 339835068.
Where did this inspection happen?
- Establishment
- LORD CORPORATION
- Site address
- 601 SOUTH STREET
- City
- SAEGERTOWN
- State
- PA
- ZIP
- 16433
- Mailing
- 601 SOUTH STREET, SAEGERTOWN, PA 16433
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 325510
- Employees
- 213
- Ownership type
- A
Citations
1 citation on file for this inspection.
1910.106 E06 I
- Issued
- Abate by
- Penalty
- Initial $7000.00 · Current $7000.00
General-duty citation text
29 CFR 1910.106(e)(6)(i): Adequate precautions were not taken to prevent the ignition of flammable vapors from sources including but not limited to open flames; lightning; smoking; cutting and welding; hot surfaces; frictional heat; static, electrical, and mechanical sparks; spontaneous ignition, including heat-producing chemical reactions; and radiant heat: A.) LORD Corporation, 601 South Street, Saegertown, PA 16433; Building 8B, TS-700 process area: Employees utilized flammable solvents including but not limited to Xylene that has a flash point of 81 degrees Fahrenheit to clean product from process vessels. A hose was used to dispense the flammable solvent into the production vessel through hatch located on top of the vessel. Procedures/practices were not established to ensure the hoses integral ground wires maintained proper electrical continuity into order to prevent static build-up and the associated discharge of static electricity. B.) LORD Corporation, 601 South Street, Saegertown, PA 16433; Building 8B, TS-700 process area: Employees utilized flammable solvents including but not limited to Xylene that has a flash point of 81 degrees Fahrenheit to clean product from process vessels. A hose was used to dispense flammable solvent into the production vessel through hatch located on top of the vessel. While dispensing the flammable the flammable solvent, the hoses nozzle was not electrically interconnected with process vessel in order to eliminate the potential for static discharge.
Recent events (1)
- — Z (S) $7000
More inspections at LORD CORPORATION
SAEGERTOWN, PA—2025-02-12
LORD CORPORATION
SAEGERTOWN, PA—2025-02-12
LORD CORPORATION
ERIE, PA—2015-04-10 00:00:00
LORD CORPORATION
ERIE, PA—2013-01-29 00:00:00
LORD CORPORATION
ERIE, PA—2012-10-26 00:00:00
LORD CORPORATION
View LORD CORPORATION's full OSHA safety record →
More inspections in this industry (NAICS 325510)
HEALDSBURG, CA—2026-07-08
RUPERT GIBBON & SPIDER, INC.
ROCKLEDGE, FL—2026-06-24
RICHARD'S PAINT MANUFACTURING CO
ROCHESTER, PA—2026-06-18
THE SHERWIN-WILLIAMS COMPANY
AUBURN, CA—2026-06-15
PRESERVA PRODUCTS LTD
FAIRLESS HILLS, PA—2026-06-09
SUDARSHAN FAIRLESS HILLS MANUFACTURING
More inspections in PA
MILTON, PA—2026-07-10
HOMETOWN FOODS CHEF BOYARDEE CO.
SUNBURY, PA—2026-07-10
DEMPSEY UNIFORM & LINEN SUPPLY, INC
LANDISVILLE, PA—2026-07-10
FAIRVIEW DEMOLITION LLC
YORK, PA—2026-07-10
AMERICAN SPECIALTY SYSTEMS INC.
WILLIAMSPORT, PA—2026-07-10
INTERNATIONAL PAINT PROS
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339835068.