Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ACTION FABRICATORS & ERECTORS, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ACTION FABRICATORS & ERECTORS, INC. in 3579 13TH. ST., NW, WASHINGTON, DC 20005 (NAICS 238120). OSHA activity number 339837585.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Action Fabricators & Erectors, INC. — free Get an email when a new federal OSHA severe-injury report for Action Fabricators & Erectors, INC. is published. One employer, no account, unsubscribe in one click.
Site address
3579 13TH. ST., NW
City
WASHINGTON
State
DC
ZIP
20005
Mailing
2305 51 ST. PL., HYATTSVILLE, MD 20781
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238120
Employees
23
Ownership type
A

2 citations on file for this inspection.

1926.351 B02

Serious Gravity 1 1 instance 3 exposed
Issued
Aug 13, 2014
Abate by
Sep 2, 2014
Penalty
Initial $1,200 · Current $600 Reduced
29 CFR 1926.351(b)(2): Welding cable(s) in use were not free from improper repair or splices for a minimum distance of 10 feet from the cable end to which the electrode holder was connected:   a)  Balcony Framing  On or about 06/30/2014, workers using an arc welder as part of a structural steel framing operation were exposed to an electrical shock hazard from a welding cable which had been repairs within 8 feet and 9 feet or the electrode holder.   Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $600
  • — Z (S) $1200

1926.404 F06

Other-than-serious 1 instance 2 exposed
Issued
Aug 13, 2014
Penalty
Initial $0 · Current $0
29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous:   a)  Balcony - On or about 06/30/2014, an extension cord used to power a portable band saw was not provided with a permanent and continuous ground, in that, the cord was missing its ground pin.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Action Fabricators & Erectors, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339837585.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.