SAN ANTONIO, TX ·
OSHA Inspection: KEYSTONE AUTOMOTIVE INDUSTRIES INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of KEYSTONE AUTOMOTIVE INDUSTRIES INC. in 4520 TEJASCO DR., SAN ANTONIO, TX 78218 (NAICS 441310). OSHA activity number 339838443.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- KEYSTONE AUTOMOTIVE INDUSTRIES INC.
- Site address
- 4520 TEJASCO DR.
- City
- SAN ANTONIO
- State
- TX
- ZIP
- 78218
- Mailing
- 4520 TEJASCO DR., SAN ANTONIO, TX 78218
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 441310
- Employees
- 40
- Ownership type
- Private (A)
Citations
5 citations on file for this inspection.
5(a)(1)
- Issued
- Sep 24, 2014
- Abate by
- Oct 14, 2014
- Penalty
- Initial $5,000 · Current $4,000 Reduced
General-duty citation text
OSH ACT of 1970 Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to a struck-by hazard: On or about July 7, 2014, and at times prior thereto, employees were exposed to a struck-by hazard; from damaged racks that are used for storage: (a) In the second warehouse area, Southwest corner of aisle #17: while loading and unloading merchandise from a damaged steel storage rack. (b) In the second warehouse area, Southwest corner of aisle #21: while loading and unloading merchandise from a damaged steel storage rack. (c) In the second warehouse area, Northeast corner of aisle #21: while loading and unloading merchandise from a damaged steel storage rack. (d) In the second warehouse area, Northeast corner of aisle #22: while loading and unloading merchandise from a damaged steel storage rack.
Recent events (2)
- · I (O) $4000
- · Z (S) $5000
1910.303 G01
- Issued
- Sep 24, 2014
- Abate by
- Oct 14, 2014
- Penalty
- Initial $7,000 · Current $5,600 Reduced
General-duty citation text
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment: On or about July 7, 2014, and at times prior thereto, employees were exposed to an electrical hazard; from not having direct unobstructed access to an electrical circuit breaker panel in case of an emergency: (a) In the forklift charging area, in the main warehouse Southwest corner: while connecting forklifts to the charging station that had 208V/240V/480V power supplied from a blocked electrical panel. (b) In the forklift charging area, in the main warehouse Northwest corner: while connecting forklifts to the charging station that had 208V/240V/480V power supplied from a blocked electrical panel.
Recent events (2)
- · I (S) $5600
- · Z (S) $7000
1910.305 B01 I
- Issued
- Sep 24, 2014
- Abate by
- Oct 14, 2014
- Penalty
- Initial $7,000 · Current $5,600 Reduced
General-duty citation text
29 CFR 1910.305(b)(1)(i): Conductors entering cutout boxes, cabinets, or fittings were not protected from abrasion, and openings through which conductors enter shall be effectively closed: Main warehouse area, Southwest corner, on or about July 7, 2014, and at times prior thereto, employees charging their forklift are exposed to an electrical hazard from exposed conductors 208V/240V/480V that are not properly secured into a junction box.
Recent events (2)
- · I (S) $5600
- · Z (S) $7000
1910.305 G02 III
- Issued
- Sep 24, 2014
- Abate by
- Oct 14, 2014
- Penalty
- Initial $7,000 · Current $0 Reduced
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief is provided that will prevent pull from being directly transmitted to joints or terminal screws: Forklift charging area in the second warehouse, South wall, on or about July 7, 2014, and at times prior thereto, employees were exposed to an electrical hazard while connecting their forklift to the forklift charger (Model: 12V0600H3C, Serial: 95 L7943) that did not have strain relief on the 208V/240V/480V flexible power feed cord.
Recent events (2)
- · I (S) $0
- · Z (S) $7000
1910.303 B01
- Issued
- Sep 24, 2014
- Abate by
- Oct 14, 2014
- Penalty
- Initial $1,000 · Current $1,000
General-duty citation text
29 CFR 1910.303(b)(1): Examination. Electric equipment shall be free from recognized hazards that are likely to cause death or serious physical harm to employees: Main warehouse area, Southwest corner, on or about July 7, 2014, and at times prior thereto, employees connecting their forklift to the charger (Model# NPC 12-3-5501, Serial#90024-20-DA) are exposed to an electrical hazard from a conductor with exposed wires.
Recent events (2)
- · I (O) $1000
- · Z (O) $1000
More inspections at Keystone Automotive Industries INC.
View Keystone Automotive Industries INC.'s full OSHA safety record →
More inspections in this industry (NAICS 441310)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339838443.