Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: HARTFORD FINISHING, INC.

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of HARTFORD FINISHING, INC. in 844 W STATE STREET, HARTFORD, WI 53027 (NAICS 332812). OSHA activity number 339840852.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Hartford Finishing, INC. — free Get an email when a new federal OSHA severe-injury report for Hartford Finishing, INC. is published. One employer, no account, unsubscribe in one click.
Site address
844 W STATE STREET
City
HARTFORD
State
WI
ZIP
53027
Mailing
844 W STATE STREET, HARTFORD, WI 53027
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332812
Employees
160
Ownership type
A

2 citations on file for this inspection.

1910.242 B

Serious Gravity 5 1 instance 2 exposed
Issued
Nov 28, 2014
Penalty
Initial $3,600 · Current $2,520 Reduced
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.:  (a) On or about September 24, 2014 near the Seghers fluidized hot sand stripping bed, compressed air gun wands used for cleaning purposes were not reduced to less than 30 p.s.i.
Recent events (2)
  • — I (S) $2520
  • — Z (S) $3600

1910.179 L03 III D

Other-than-serious 1 instance 2 exposed
Issued
Nov 28, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.179(l)(3)(iii)(d): Pendant control stations were not kept clean, and/or their function labels were not kept legible:  (a) On or about September24, 2014, the pendant control push button switches for the overhead crane at the Seghers fluidized hot sand stripping bed were not maintained in a clean legible condition.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Hartford Finishing, INC.'s full OSHA safety record →