Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: LUECK'S HOME IMPROVEMENTS INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of LUECK'S HOME IMPROVEMENTS INC. in 706 SOUTH MAIN STREET, OSHKOSH, WI 54902 (NAICS 444110). OSHA activity number 339850281.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Lueck'S Home Improvements INC. — free Get an email when a new federal OSHA severe-injury report for Lueck'S Home Improvements INC. is published. One employer, no account, unsubscribe in one click.
Site address
706 SOUTH MAIN STREET
City
OSHKOSH
State
WI
ZIP
54902
Mailing
706 SOUTH MAIN STREET, OSHKOSH, WI 54902
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
444110
Employees
20
Ownership type
A

5 citations on file for this inspection.

1910.23 C01

Serious Gravity 5 1 instance 18 exposed
Issued
Aug 8, 2014
Abate by
Sep 15, 2014
Penalty
Initial $1,600 · Current $1,120 Reduced
29 CFR 1910.23(c)(1): Every open-sided floor or platform 4 feet or more above adjacent floor or ground level shall be guarded by a standard railing (or the equivalent as specified in paragraph (e)(3) of this section) on all open sides except where there is entrance to a ramp, stairway, or fixed ladder. The railing shall be provided with a toeboard wherever, beneath the open sides persons can pass:  a)    Mezzanine had approximately an 8 foot wide section without guard rails where materials were being stored. This storage was approximately 9 feet off the ground.
Recent events (2)
  • — I (S) $1120
  • — Z (S) $1600

1910.23 E01

Serious Gravity 5 1 instance 18 exposed
Issued
Aug 8, 2014
Abate by
Sep 15, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.23(e)(1): A standard railing shall consist of top rail, intermediate rail, and posts, and shall have a vertical height of 42 inches nominal from upper surface of top rail to floor, platform, runway, or ramp level. The top rail shall be smooth-surfaced throughout the length of the railing. The intermediate rail shall be approximately halfway between the top rail and the floor, platform, runway, or ramp. The ends of the rails shall not overhang the terminal posts except where such overhang does not constitute a projection hazard:  a)    Mezzanine had a chain and pipe railing with no mid-rail or toe boards. This storage was approximately 9 feet off the ground.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1904.40 A

Other-than-serious 3 instances 32 exposed
Issued
Aug 8, 2014
Abate by
Aug 22, 2014
Penalty
Initial $400 · Current $280 Reduced
29 CFR 1904.40(a): The employer did not provide an authorized government representative the records within the four business hours:  a)    On or about 7/15/2014 employer failed to provide copies of the injury and illness records to the authorized representative completing the inspection at the site.
Recent events (2)
  • — I (O) $280
  • — Z (O) $400

1910.22 D01

Other-than-serious 3 instances 18 exposed
Issued
Aug 8, 2014
Abate by
Sep 15, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.22(d)(1): On every building or other structure, or part thereof, used for mercantile, business, industrial or storage purposes, the loads approved by the building official were not marked on plates of approved design and securely affixed in a conspicuous place in each space to which they relate:  a)    Warehouse part of building did not have load limits posted for the storage mezzanines.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.1200 E01

Other-than-serious 1 instance 18 exposed
Issued
Aug 8, 2014
Abate by
Sep 15, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met:  a)    The employer had not developed and/or implemented a written hazard communication program. Hazardous chemicals were being used which included: Goof Off Professional Strength Remover.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Lueck'S Home Improvements INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339850281.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.