BISHOP, TX —
OSHA Inspection: OXEA BISHOP, LLC
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of OXEA BISHOP, LLC in HIGHWAY 77 SOUTH, BISHOP, TX 78343 (NAICS 325110). OSHA activity number 339850547.
Where did this inspection happen?
- Establishment
- OXEA BISHOP, LLC
- Site address
- HIGHWAY 77 SOUTH
- City
- BISHOP
- State
- TX
- ZIP
- 78343
- Mailing
- P.O. BOX 9, BISHOP, TX 78343
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 325110
- Employees
- 39
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.119 D03 I B
- Issued
- Abate by
- Penalty
- Initial $4900.00 · Current $4900.00
General-duty citation text
29 CFR 1910.119(d)(3)(i)(B): Piping and instrument diagrams (P&ID's); This violation was most recently observed on about December 15, 2014 in the TMP(Trimethylolpropane) Unit at OXEA Corporation located in Bishop, Texas when the employer failed to document and maintain accurate process safety information (PSI) such as but not limited to Piping and Instrument Diagrams (P&ID) when the new pump P-90117 and its associated piping were added to the facility.
Recent events (2)
- — I (O) $4900
- — Z (S) $4900
1910.119 D03 II
- Issued
- Abate by
- Penalty
- Initial $4900.00 · Current $4900.00
General-duty citation text
29 CFR 1910.119(d)(3)(ii): The employer shall document that equipment complies with recognized and generally accepted good engineering practices. Instance a) This violation was most recently observed on about December 15, 2014 in the 1,3 Butylene Glycol Unit at OXEA Corporation located in Bishop, Texas when the employer did not ensure that the Hydrogen reactor T-221 has a manufacturer nameplate. Instance b) This violation was most recently observed on about December 15, 2014 in the 1,3 BG Unit at OXEA Corporation located in Bishop, Texas when the employer did not ensure that the manufacturer nameplate on Hydrogen reactor T-222 is legible.
Recent events (2)
- — I (O) $4900
- — Z (S) $4900
1910.119 J05
- Issued
- Abate by
- Penalty
- Initial $4900.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.119(j)(5): Equipment deficiencies. The employer shall correct deficiencies in equipment that are outside acceptable limits (defined by the process safety information in paragraph (d) of this section) before further use or in a safe and timely manner when necessary means are taken to assure safe operation. This violation was most recently observed on about December 15, 2014 in the TMP(Trimethylolpropane)Unit at OXEA Corporation located in Bishop, Texas when the employer operated process equipment with deficient structural supports, such as but not limited to damaged concrete fireproofing on structural supports of T-223 Light Ends Column and its reboiler HE-1124.
Recent events (2)
- — I (S) $0
- — Z (S) $4900
1910.151 C
- Issued
- Penalty
- Initial $2800.00 · Current $2800.00
General-duty citation text
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use: At this location eyewash station were not clear from overhead obstruction, exposing employees to struck-by hazard.
Recent events (2)
- — I (O) $2800
- — Z (S) $2800
More inspections at OXEA BISHOP, LLC
BISHOP, TX—2010-10-12 00:00:00
OXEA BISHOP LLC
View OXEA BISHOP, LLC's full OSHA safety record →
More inspections in this industry (NAICS 325110)
GEISMAR, LA—2026-05-28
RUBICON
PALMER, AK—2026-04-16
AIRGAS, INC.
HOUSTON, TX—2026-02-09
TPC GROUP LLC
CALVERT CITY, KY—2025-12-16
68663 - WESTLAKE VINYLS INC
CINCINNATI, OH—2025-12-04
KOST USA LLC
More inspections in TX
SPRING, TX—2026-07-10
DORSTENER WIRE TECH INC.
FORT WORTH, TX—2026-07-10
RC PROFESSIONAL ROOFING OF TEXAS LLC
CYPRESS, TX—2026-07-10
FEDERICO CARVAJAL GARCIA
SAN ANTONIO, TX—2026-07-10
ED LONG'S METAL WORKS
SAN ANTONIO, TX—2026-07-09
WAREHOUSE RACK COMPANY, LP
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339850547.