Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: STOEVER-PARKER ELECTRIC INC.

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of STOEVER-PARKER ELECTRIC INC. in 8233 N. SAM HOUSTON PKWY. E., HUMBLE, TX 77396 (NAICS 238210). OSHA activity number 339851222.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Stoever-Parker Electric INC. — free Get an email when a new federal OSHA severe-injury report for Stoever-Parker Electric INC. is published. One employer, no account, unsubscribe in one click.
Site address
8233 N. SAM HOUSTON PKWY. E.
City
HUMBLE
State
TX
ZIP
77396
Mailing
6404 HAMMAN, HOUSTON, TX 77007
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238210
Employees
12
Ownership type
A

1 citation on file for this inspection.

1926.405 B01

Serious Gravity 5 2 instances 12 exposed
Issued
Jul 17, 2014
Penalty
Initial $3,500 · Current $2,100 Reduced
29 CFR 1926.405(b)(1): Unused openings in cabinets, boxes, and fittings were not effectively closed:   The employer does not ensure that unused openings in boxes, cabinets, or fittings are effectively closed.      a) This violation was observed on or about July 15, 2014, located on the first floor where employees were exposed to electrical hazards when a temporary breaker panel used to power cameras and outlets had open circuit breaker slots which were not covered.    b) This violation was observed on or about July 15, 2014, located on the first floor where employees were exposed to electrical hazards when a temporary breaker panel used to power cameras and outlets had an open knockout that was not covered on the left side.       Pursuant to 29 C.F. R. 1903.19, within ten (10) calendar days of the abatement date, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that that unused openings in boxes, cabinets, or fittings are effectively closed.
Recent events (2)
  • — I (S) $2100
  • — Z (S) $3500

View Stoever-Parker Electric INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339851222.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.