IDAHO FALLS, ID ·
OSHA Inspection: BOISE CASCADE MATERIALS DISTRIBUTION
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of BOISE CASCADE MATERIALS DISTRIBUTION in 3890 BOMBARDIER AVE., IDAHO FALLS, ID 83403 (NAICS 321911). OSHA activity number 339852618.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- BOISE CASCADE MATERIALS DISTRIBUTION
- Site address
- 3890 BOMBARDIER AVE.
- City
- IDAHO FALLS
- State
- ID
- ZIP
- 83403
- Mailing
- 3890 BOMBARDIER AVE., IDAHO FALLS, ID 83403
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 321911
- Employees
- 22
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.213 C01
- Issued
- Oct 2, 2014
- Abate by
- Oct 29, 2014
- Penalty
- Initial $3,400 · Current $2,380 Reduced
General-duty citation text
29 CFR 1910.213(c)(1): Circular handfed ripsaw was not guarded by an automatically adjusting hood which completely enclosed that portion of the saw above the table and above the material being cut: a) Door Shop: On or about 7-16-2014, employee was using a table saw to cut material without the blade guard installed. Note: Abatement certification is required for this item.
Recent events (2)
- · I (S) $2380
- · Z (S) $3400
1910.305 G02 III
- Issued
- Oct 2, 2014
- Abate by
- Oct 29, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws: a) Door shop: The flexible cord supplying power to the door mortising machine was not secured into the cord cap strain relief device. Note: Abatement certification is required for this item