Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: KOBEL CONSTRUCTION INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of KOBEL CONSTRUCTION INC. in 1943-45 N. LATROBE AVE., CHICAGO, IL 60639 (NAICS 238160). OSHA activity number 339853194.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Kobel Construction INC. — free Get an email when a new federal OSHA severe-injury report for Kobel Construction INC. is published. One employer, no account, unsubscribe in one click.
Site address
1943-45 N. LATROBE AVE.
City
CHICAGO
State
IL
ZIP
60639
Mailing
7649 W. ADDISON AVE. APT 2E, CHICAGO, IL 60634
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
3
Ownership type
A

4 citations on file for this inspection.

1926.416 A01

Serious Gravity 10 1 instance 2 exposed
Issued
Dec 8, 2014
Penalty
Initial $2,800 · Current $1,400 Reduced
29 CFR 1926.416(a)(1): Employees were permitted to work in proximity to electric power circuits and were not protected against electric shock by de-energizing and grounding the circuits or effectively guarding the circuits by insulation or other means:      a)  On or about June 9, 2014, employees were not protected against accidental contact with energized overhead power lines during roofing work along south edge of the low sloped roof.  The overhead power lines consisted of primary lines having a voltage rating of 7200 volts.       No abatement certification or documentation is required for this item.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2800

1926.416 A03

Serious Gravity 10 1 instance 3 exposed
Issued
Dec 8, 2014
Abate by
Dec 12, 2014
Penalty
Initial $2,800 · Current $1,400 Reduced
29 CFR 1926.416(a)(3):  Before work began, the employer did not ascertain by inquiry, direct observation, or by instruments, whether any part of an energized electric power circuit, exposed or concealed, was so located that the performance of the work could bring any person, tool, or machine into physical or electrical contact with the electric power circuit:    a)  On or about June 9, 2014, the employer did not determine that the power lines located along the south edge of the roof were de-energized and/or insulated to protect employees, engaged in roofing work, from the accidental contact with potentially live parts.      In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2800

1926.501 B10

Serious Gravity 10 1 instance 3 exposed
Issued
Dec 8, 2014
Abate by
Dec 12, 2014
Penalty
Initial $2,800 · Current $1,400 Reduced
29 CFR 1926.501(b)(10):  Each employee engaged in roofing activities on low-slope roofs, with unprotected sides and edges 6 feet (1.8 m) or more above lower levels was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system:      a)  On or about June 9, 2014, employees were not protected from the hazard of falling while performing roofing work on low-sloped roof with a ground to eave height of approximately 18 feet.      In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2800

1926.503 A01

Serious Gravity 5 1 instance 3 exposed
Issued
Dec 8, 2014
Abate by
Jan 12, 2015
Penalty
Initial $2,000 · Current $1,000 Reduced
29 CFR 1926.503(a)(1):  The employer did not provide a training program for each employee who might be exposed to fall hazards:      a)  On or about June 9, 2014, employer did not provide training to each employee in order to recognize hazards associated with working at an elevation and to understand procedures to control or minimize those hazards.      In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2000

View Kobel Construction INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339853194.