Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: WILLIAMSON-DICKIE MFG. CO.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of WILLIAMSON-DICKIE MFG. CO. in 510 S. HIGHWAY 83, UVALDE, TX 78801 (NAICS 315225). OSHA activity number 339854747.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Williamson-Dickie MFG. CO. — free Get an email when a new federal OSHA severe-injury report for Williamson-Dickie MFG. CO. is published. One employer, no account, unsubscribe in one click.
Site address
510 S. HIGHWAY 83
City
UVALDE
State
TX
ZIP
78801
Mailing
510 S. HIGHWAY 83, UVALDE, TX 78801
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
315225
Employees
182
Ownership type
A

2 citations on file for this inspection.

1910.262 C05

Serious Gravity 1 1 instance 2 exposed
Issued
Sep 24, 2014
Abate by
Oct 14, 2014
Penalty
Initial $3,000 · Current $1,800 Reduced
29 CFR 1910.262(c)(5): Inspection and maintenance. All guards and other safety devices, including starting and stopping devices, were not properly maintained:        Production line, Southwest cutter #7, on or about July 17, 2014, and at times prior thereto, employees operating the fabric Gerber cutter #7 were exposed to a struck-by hazard from the automated bridge fabric cutter head that does not have a functioning emergency stop.
Recent events (2)
  • — I (S) $1800
  • — Z (S) $3000

1910.305 G01 IV A

Serious Gravity 1 1 instance 1 exposed
Issued
Sep 24, 2014
Abate by
Oct 4, 2014
Penalty
Initial $3,000 · Current $1,800 Reduced
29 CFR 1910.305(g)(1)(iv)(A): A flexible cord was used as a substitute for the fixed wiring of a structure;   Fabric lifting station, South side, on or about July 17, 2014, and at times prior thereto, employees were exposed to an electrical hazard from a flexible cord that was being used to power a Dayton Electric Hoist (800 lb. capacity) and was hung over a metal beam in such a method that it damage the outer jacket.
Recent events (2)
  • — I (S) $1800
  • — Z (S) $3000

View Williamson-Dickie MFG. CO.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339854747.