Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: BRAND ENERGY SOLUTIONS

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of BRAND ENERGY SOLUTIONS in 5900 HWY 225, DEER PARK, TX 77536 (NAICS 238320). OSHA activity number 339855801.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Brand Energy Solutions — free Get an email when a new federal OSHA severe-injury report for Brand Energy Solutions is published. One employer, no account, unsubscribe in one click.
Site address
5900 HWY 225
City
DEER PARK
State
TX
ZIP
77536
Mailing
4904 RAILROAD STREET, DEER PARK, TX 77536
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238320
Employees
500
Ownership type
A

2 citations on file for this inspection.

1910.134 D01 III

Other-than-serious 12 instances 8 exposed
Issued
Sep 16, 2014
Abate by
Oct 19, 2014
Penalty
Initial $6,000 · Current $5,000 Reduced

Hazardous substances 9135A102

29 CFR 1910.134(d)(1)(iii): The employer did not identify and evaluate the respiratory hazard(s) in the workplace; including a reasonable estimate of employee exposures to respiratory hazards and identification of the contaminant's chemical state and physical form: (Construction Reference 1926.103)    (a) at Shell Deer Park, Aromatics Concentration Unit (ACU), enclosure "Z", employees are exposed to inhalation hazards while conducting a Thermal Spray Aluminum process using half-face respiratory protection.  The contaminants and levels of aluminum, beryllium, hexavalent chromium, copper, lead, magnesium, manganese, nickel, iron, vanadium, and zinc oxide have not been determined to ensure adequate respiratory protection.    (b) at Shell Deer Park, ACU, enclosure "Z", employees are exposed to inhalation hazards in a confined space during surface coating removal.  The levels of respirable dust have not been measured to ensure adequate engineering controls.
Recent events (2)
  • — I (O) $5000
  • — Z (S) $6000

1910.1200 H03 II

Other-than-serious 1 instance 4 exposed
Issued
Sep 16, 2014
Abate by
Oct 19, 2014
Penalty
Initial $4,000 · Current $2,500 Reduced
29 CFR 1910.1200(h)(3)(ii): Employee training did not include the physical and health hazards of the chemicals in the work area (Construction Reference 1926.59):    a) at Shell Deer Park, ACU, containment # 7, employees had not received effective training on the inhalation hazards involving thermal spray aluminum (TSA).  This process produces hazardous chemicals such as metal fumes, carbon monoxide, carbon dioxide, nitrogen oxides, ozone and respirable dusts.
Recent events (2)
  • — I (O) $2500
  • — Z (S) $4000

View Brand Energy Solutions's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339855801.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.