Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: R & C CONSTRUCTION

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of R & C CONSTRUCTION in 1739 GRANT STREET, BLAIR, NE 68008 (NAICS 238160). OSHA activity number 339862039.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch R & C Construction — free Get an email when a new federal OSHA severe-injury report for R & C Construction is published. One employer, no account, unsubscribe in one click.
Establishment
R & C CONSTRUCTION
Site address
1739 GRANT STREET
City
BLAIR
State
NE
ZIP
68008
Mailing
4225 S 37TH STREET, OMAHA, NE 68107
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
3
Ownership type
A

4 citations on file for this inspection.

1926.152 A01

Serious Gravity 5 1 instance 1 exposed
Issued
Sep 18, 2014
Abate by
Oct 23, 2014
Penalty
Initial $1,600 · Current $1,600
29 CFR 1926.152(a)(1): Containers and portable tanks used for the storage and handling of flammable and combustible liquids were not approved:      1739 Grant St., Blair, NE 68008 (Job-site): The employer did not ensure that its employees were storing gasoline in an approved gasoline cans. The employees were using a plastic portable diesel container to store gasoline.      Abatement certification is required for this violation.  Abatement certification sheet is enclosed with this citation.
Recent events (3)
  • — A (S) $1600
  • — I (S) $800
  • — Z (S) $1600

1926.307 D01

Serious Gravity 10 1 instance 1 exposed
Issued
Sep 18, 2014
Abate by
Oct 23, 2014
Penalty
Initial $2,800 · Current $2,800
29 CFR 1926.307(d)(1):  Pulley(s) with part(s) seven feet (2.128 m) or less from the floor or work  platform were not guarded in accordance with the requirements specified in paragraphs  (m) and  (o) of this section:      1739 Grant St., Blair, NE 68008 (Job-site): The employer did not ensure that a pulley was adequately guarded on the Ridgid air compressor.        Abatement certification and abatement documentation is required for this violation.  The documentation should include written verification of abatement, applicable measurements or monitoring results, and photographs or videos which you believe will be helpful.  The abatement certification sheet is enclosed.
Recent events (3)
  • — A (S) $2800
  • — I (S) $1400
  • — Z (S) $2800

1926.307 E03 I

Serious Gravity 10 1 instance 1 exposed
Issued
Sep 18, 2014
Abate by
Oct 23, 2014
Penalty
Initial $0 · Current $0
29 CFR 1926.307(e)(3)(i):  Vertical and inclined belts were not enclosed by a guard conforming  to standards in paragraphs (m) and (o) of this section:      1739 Grant St., Blair, NE 68008 (Job-site): The employer is failing to ensure that the inclined belt was adequately guarded on the Ridgid air compressor.      Abatement certification and abatement documentation is required for this violation.  The documentation should include written verification of abatement, applicable measurements or monitoring results, and photographs or videos which you believe will be helpful.  The abatement certification sheet is enclosed.
Recent events (3)
  • — A (S) $0
  • — I (S) $0
  • — Z (S) $0

1926.501 B13

Serious Gravity 10 1 instance 2 exposed
Issued
Sep 18, 2014
Abate by
Oct 23, 2014
Penalty
Initial $2,800 · Current $2,800
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet or more above lower levels was not protected by guardrail systems, safety net systems, or personal fall arrest systems, nor was an alternative fall protection plan which meets the requirements of �1926.502(k) developed and implemented.                                                                                                             1739 Grant St., Blair, NE 68008 (Job-site): The employer is failing ensure that fall protection was provided for employees who were working on the roof of a home which was approximately 11 feet from a lower level.    Abatement certification and abatement documentation is required for this violation.  The documentation should include written verification of abatement, applicable measurements or monitoring results, and photographs or videos which you believe will be helpful.  The abatement certification sheet is enclosed.
Recent events (3)
  • — A (S) $2800
  • — I (S) $2800
  • — Z (S) $2800

View R & C Construction's full OSHA safety record →