OXFORD, NY ·
OSHA Inspection: AUTOMECHA MANUFACTURING, LTD
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of AUTOMECHA MANUFACTURING, LTD in 48 S. CANAL STREET, OXFORD, NY 13830 (NAICS 333313). OSHA activity number 339863268.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- AUTOMECHA MANUFACTURING, LTD
- Site address
- 48 S. CANAL STREET
- City
- OXFORD
- State
- NY
- ZIP
- 13830
- Mailing
- 48 S. CANAL STREET, OXFORD, NY 13830
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 333313
- Employees
- 15
- Ownership type
- Private (A)
Citations
6 citations on file for this inspection.
1910.106 E06 I
- Issued
- Aug 4, 2014
- Abate by
- Aug 17, 2014
- Penalty
- Initial $1,600 · Current $960 Reduced
General-duty citation text
29 CFR 1910.106(e)(6)(i): Adequate precautions against the ignition of flammable vapors were not taken: a) Spray Booth Area, on or about 7/23/14: Two 55 gallon drums and one 16 gallon container of lacquer thinner were being used without grounding the containers.
Recent events (2)
- · I (S) $960
- · Z (S) $1600
1910.107 G02
- Issued
- Aug 4, 2014
- Abate by
- Aug 27, 2014
- Penalty
- Initial $2,400 · Current $1,440 Reduced
General-duty citation text
29 CFR 1910.107(g)(2): Spraying area(s) were not kept free from the accumulation of deposits of combustible residues: a) Left Spray Booth, on or about 7/23/14: There was an accumulation of combustible residues on the hanging hooks and paint stands. Employees spray paint with Class 1B Flammable materials. b) Right Spray Booth, on or about 7/23/14: There was an accumulation of combustible residues on the hanging hooks and paint stands. Employees spray paint with Class 1B Flammable materials.
Recent events (2)
- · I (S) $1440
- · Z (S) $2400
1910.147 C01
- Issued
- Aug 4, 2014
- Abate by
- Sep 6, 2014
- Penalty
- Initial $2,000 · Current $1,200 Reduced
General-duty citation text
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of energy control procedures, employee training, and periodic inspections to ensure that before any employee performing any servicing or maintenance on a machine or equipment where the unexpected energizing, start up or release of stored energy could occur and cause injury, the machine or equipment would be isolated from the energy source and rendered inoperative. a) Automecha Manufacturing, Ltd., on or about 7/23/14: The employer had not established an energy control program consisting of energy control procedures, employee training and periodic inspections for employees who perform servicing and/or maintenance on various machinery or equipment such as but not limited to: Amada Punch Press; CNC Machines and Wysong Shear.
Recent events (2)
- · I (S) $1200
- · Z (S) $2000
1910.212 A01
- Issued
- Aug 4, 2014
- Abate by
- Sep 6, 2014
- Penalty
- Initial $2,000 · Current $1,200 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created point of operation, rotating parts, and flying chips: a) Fabrication Area, on or about 7/23/14: Wysong Shear was not provided with a point of operation guard. b) Fabrication Area, on or about 7/23/14: Four Delta Drill Presses were not provided with a chuck and tool guard. c) Fabrication Area, on or about 7/23/14: Walker Turner Drill Press was not provided with a chuck and tool guard. d) Fabrication Area, on or about 7/23/14: Startrite H250A Band Saw was not protected with a guard on the unused portion of the blade on the left and right side. e) Out Back Area, on or about 7/23/14: Two Bridgeport Drill Press were not provided with a chuck and tool guard. f) Out Back Area, on or about 7/23/14: Nardini NS 1440E Lathe did not have the rotating chuck guarded. g) Out Back Area, on or about 7/23/14: Clausing Drill Press was not provided with a chuck and tool guard.
Recent events (2)
- · I (S) $1200
- · Z (S) $2000
1910.303 B02
- Issued
- Aug 4, 2014
- Abate by
- Nov 30, 2014
- Penalty
- Initial $2,800 · Current $1,680 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: a) XL Assembly Area, on or about 7/23/14: Flexible cords hanging from ceiling with a duplex metal receptacle box and a quad metal receptacle box attached used to provide power to items in the area. Metal boxes are listed for permanent mounting only. b) P8 Assembly Area, on or about 7/23/14: Flexible cords hanging from ceiling with a duplex metal receptacle box and a quad metal receptacle box attached used to provide power to items in the area. Metal boxes are listed for permanent mounting only. c) Test Area, on or about 7/23/14: Flexible cord hanging from ceiling with a duplex metal receptacle box attached used to provide power to items in the area. Metal box is listed for permanent mounting only. d) ET Assembly Area, on or about 7/23/14: Flexible cords hanging from ceiling with Six quad duplex metal receptacles boxes attached used to provide power to items in the area. Metal boxes are listed for permanent mounting only.
Recent events (2)
- · I (S) $1680
- · Z (S) $2800
1910.303 G02 I
- Issued
- Aug 4, 2014
- Abate by
- Aug 17, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(g)(2)(i): Live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by approved cabinets or other forms of approved enclosures, or other means listed under this provision: a) Fabrication Area, on or about 7/23/14: A 220 volt Breaker Panel Box No. 7 had one blank missing. a) CNC Area, on or about 7/23/14: A 240 volt Breaker Panel Box No. 9 had one blank missing.
Recent events (2)
- · I (S) $0
- · Z (S) $0
More inspections in this industry (NAICS 333313)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339863268.