HOUSTON, TX —
OSHA Inspection: JM SIDING CONSTRUCTION, INC.
Unprogrammed Other inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Other safety inspection of JM SIDING CONSTRUCTION, INC. in 2111 WESTHEIMER, HOUSTON, TX 77098 (NAICS 238130). OSHA activity number 339867004.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- JM SIDING CONSTRUCTION, INC.
- Site address
- 2111 WESTHEIMER
- City
- HOUSTON
- State
- TX
- ZIP
- 77098
- Mailing
- 1411 WEST SEALY STREET, ALVIN, TX 77511
What kind of inspection was it?
- Inspection type
- Unprogrammed Other (I)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- Employees
- 6
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.452 J01
- Issued
- Jul 28, 2014
- Abate by
- Jul 30, 2014
- Penalty
- Initial $2,000 · Current $1,200 Reduced
General-duty citation text
29 CFR 1926.452(j)(1): Pump jack brackets, braces, and accessories were not fabricated from metal plates and angles: a) On the east face of Building B, the bracing used for a pump jack scaffold was not metal. Employees were installing Tyvek from the pump jack scaffold, more than 29 feet above the ground.
Recent events (2)
- — I (S) $1200
- — Z (S) $2000
1926.452 J02
- Issued
- Jul 28, 2014
- Abate by
- Jul 30, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.452(j)(2): Poles were not secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary: a) On the east face of Building B, the poles supporting a pump jack scaffold were not secured at the top and the bottom. Employees were installing Tyvek from the pump jack scaffold, more than 29 feet above the ground.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.453 B02 V
- Issued
- Jul 28, 2014
- Abate by
- Jul 30, 2014
- Penalty
- Initial $2,000 · Current $1,200 Reduced
General-duty citation text
29 CFR 1926.453(b)(2)(v): A body belt with lanyard attached to the boom or basket was not worn by employee(s) working from an aerial lift: a) On the west face of Building B, an employee installing Tyvek from an aerial lift, more than 45 feet above the ground, did not have a lanyard attached to the boom or basket.
Recent events (2)
- — I (S) $1200
- — Z (S) $2000
More inspections at JM Siding Construction, INC.
View JM Siding Construction, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238130)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339867004.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.