OSHA Inspection: LUSA CONSTRUCTION INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of LUSA CONSTRUCTION INC. in 380 BELLEVILLE PIKE, NORTH ARLINGTON, NJ 07031 (NAICS 236220). OSHA activity number 339871105.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Lusa Construction INC. — free Get an email when a new federal OSHA severe-injury report for Lusa Construction INC. is published. One employer, no account, unsubscribe in one click.
Site address
380 BELLEVILLE PIKE
City
NORTH ARLINGTON
State
NJ
ZIP
07031
Mailing
52 PORRETTE AVE, NORTH ARLINGTON, NJ 07031
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236220
Employees
5
Ownership type
A

1 citation on file for this inspection.

1926.451 F06

Repeat Gravity 10 3 instances 3 exposed
Issued
Oct 2, 2014
Penalty
Initial $14,000 · Current $6,000 Reduced
29 CFR 1926.451(f)(6): Scaffolds were erected, used, dismantled, altered, or moved such that they, or any conductive material handled on them, could have come closer than the minimum distances established for specific voltages as set forth in the table in subparagraph (f)(6).      Less Than 300 V - minimum distance required - 3 feet     Between 300 V and 50 KV - minimum distance required - 10 feet          a) Scaffold on Elm St.: Workers engaged in stucco activities from a 4 frame high tubular welded scaffold approximately 5 feet from a 13KV Primary were exposed to an electrocution hazard, on or about 4/3/2014.    b) Scaffold on Elm St.: Workers engaged in stucco activities from a pump jack scaffold touching the 240V secondary were exposed to an electrocution hazard, on or about 4/3/2014.    c) Scaffold on the roof.: Workers engaged in stucco activities from a 1 frame high tubular welded scaffold approximately 1 foot from the 240V secondary were exposed to an electrocution hazard, on or about 4/3/2014.
Recent events (3)
  • — C (W) $14000
  • — F (R) $6000
  • — Z (W) $14000

View Lusa Construction INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339871105.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.