GLENCOE, IL —
OSHA Inspection: MARECKI MASONRY, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of MARECKI MASONRY, INC. in 421 MADISON AVE., GLENCOE, IL 60022 (NAICS 238140). OSHA activity number 339879413.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MARECKI MASONRY, INC.
- Site address
- 421 MADISON AVE.
- City
- GLENCOE
- State
- IL
- ZIP
- 60022
- Mailing
- 8602 N. OLCOTT AVE., NILES, IL 60714
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238140
- Employees
- 12
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.100 A
- Issued
- Sep 17, 2014
- Abate by
- Sep 23, 2014
- Penalty
- Initial $1,600 · Current $800 Reduced
General-duty citation text
29 CFR 1926.100(a): Employees were not protected by protective helmets while working in areas where there was a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns: a) Employees were not wearing protective helmets where there was a possible danger of head injury. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
- — I (S) $800
- — Z (S) $1600
1926.451 B01
- Issued
- Sep 17, 2014
- Abate by
- Sep 23, 2014
- Penalty
- Initial $2,800 · Current $1,400 Reduced
General-duty citation text
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii): a) Employees were exposed to the hazard of falling, approximately 18 feet to the ground, while performing masonry work from tubular welded frame scaffold platform that was not fully planked. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S) $1400
- — Z (S) $2800
1926.451 G01
- Issued
- Sep 17, 2014
- Abate by
- Sep 23, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet above a lower level was not protected from falling to that lower level: a) Employees were exposed to the hazard of falling approximately 18 feet to the ground, while performing masonry work from tubular welded frame scaffold platform. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.451 C01 II
- Issued
- Sep 17, 2014
- Abate by
- Sep 23, 2014
- Penalty
- Initial $2,000 · Current $1,000 Reduced
General-duty citation text
29 CFR 1926.451(c)(1)(ii): Guys, ties, and/or braces were not installed according to the scaffold manufacturer's recommendations or at the closest horizontal member to the 4:1 height and repeated vertically at locations of horizontal members every 20 feet (56.1 m) or less thereafter for scaffolds 3 feet ((0.91 m) wide or less, and every 26 feet (7.9 m) or less thereafter for scaffolds greater than 3 feet (0.91m) wide: a) Employees were working from a tubular welded frame scaffold that was six frames high and was not tied to the building. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
- — I (S) $1000
- — Z (S) $2000
1926.501 B13
- Issued
- Sep 17, 2014
- Penalty
- Initial $1,600 · Current $800 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet or more above lower levels was not protected by guardrail systems, safety net systems, or personal fall arrest systems, nor did the employer demonstrate that it is infeasible or creates a greater hazard to use these systems and develop and implement a fall protection plan which meets the requirements of paragraph (k) of section 1926.502: a) Employees were not protected from the hazard of falling approximately 7.5 feet to the lower level while walking and working around unguarded window well. No abatement certification or documentation is required for this item.
Recent events (2)
- — I (S) $800
- — Z (S) $1600
More inspections at Marecki Masonry, INC.
View Marecki Masonry, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238140)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339879413.