Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: DUKANE PRECAST INCORPORATED

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of DUKANE PRECAST INCORPORATED in 13733 S US RTE 30, PLAINFIELD, IL 60544 (NAICS 238110). OSHA activity number 339883423.

Watch Dukane Precast Incorporated — free Get an email when a new federal OSHA severe-injury report for Dukane Precast Incorporated is published. One employer, no account, unsubscribe in one click.
Site address
13733 S US RTE 30
City
PLAINFIELD
State
IL
ZIP
60544
Mailing
1805 HIGH GROVE LANE SUITE 137, NAPERVILLE, IL 60540
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238110
Employees
30
Ownership type
A

6 citations on file for this inspection.

1910.146 D02

Deleted Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $4950.00 · Current $0.00 Reduced
29 CFR 1910.146(d)(2): Under the permit space program required by paragraph (c)(4) of this section, the employer shall identify and evaluate the hazards of permit spaces before employees enter them:  a) On or about June 5, 2014, Dukane Precast Incorporated had not evaluated the potential atmospheric hazards posed by the presence of natural gas at the Batch Plant Drive-Over Pit before an authorized employee entered the permit space for cleaning.  b) On or about June 24, 2014, Dukane Precast Incorporated had not evaluated the potential atmospheric hazards posed by the presence of natural gas at the Burnham Boiler before an authorized employee entered the permit space for cleaning and maintenance.  Thereby, employee(s) required to enter the permit spaces for cleaning and maintenance were exposed to a potential hazardous atmosphere: (1) Flammable gas in excess of 10 percent of it's lower flammable limit (2) Atmospheric oxygen concentration below 19.5 percent.
Recent events (3)
  • — F (S) $0
  • — C (S) $4950
  • — Z (S) $4950

1910.146 D03 III

Deleted Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.146(d)(3)(iii): Under the permit space program required by paragraph (c)(4) of this section, the employer shall develop and implement the means, procedures, and practices necessary for safe permit space entry operations, including, but not limited to, isolating the permit space:  a) On or about June 5, 2014, Dukane Precast Incorporated had not developed and implemented the means, procedures, and practices for isolating the Batch Plant Drive-Over Pit from the potential atmospheric hazards posed by the presence of natural gas during an authorized entry for cleaning.  b) On or about June 24, 2014, Dukane Precast Incorporated had not developed and implemented the means, procedures, and practices for isolating the Burnham Boiler from the potential atmospheric hazards posed by the presence of natural gas during an authorized entry for cleaning and maintenance.  Thereby, employee(s) required to enter the permit spaces for cleaning and maintenance were exposed to a potential hazardous atmosphere: (1) Flammable gas in excess of 10 percent of it's lower flammable limit (2) Atmospheric oxygen concentration below 19.5 percent.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.146 F08

Other-than-serious 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $4950.00 · Current $5940.00
29 CFR 1910.146(f)(8): The entry permit that documents compliance with this section and authorizes entry to a permit space shall identify the measures used to isolate the permit space and to eliminate or control permit space hazards before entry:    On or about August 4, 2014, Dukane Precast Incorporated had not identified on the entry permits for authorized entries into the concrete mixer the measures used to isolate the permit space from the hazards of the concrete mixing system including process materials such as sand, aggregate and water.  Thereby, employee(s) required to enter the mixer for cleaning and maintenance activities were exposed to a potential engulfment hazard.
Recent events (3)
  • — F (O) $5940
  • — C (S) $4950
  • — Z (S) $4950

1910.146 G01

Deleted Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $4950.00 · Current $0.00 Reduced
29 CFR 1910.146(g)(1): The employer shall provide training so that all employees whose work is regulated by this section acquire the understanding, knowledge, and skills necessary for the safe performance of the duties assigned under this section:  On or about June 5, 2014, Dukane Precast Incorporated had not provided authorized employee(s) required to enter the Batch Plant Drive-Over Pit, a permit-required confined space, with effective training, including, isolation of the natural gas prior to entry.   On or about June 24, 2014, Dukane Precast Incorporated had not provided authorized employee(s) required to enter the Burnham Boiler, a permit-required confined space, with effective training, including, isolation of the natural gas prior to entry.     Thereby, employee(s) required to enter the permit spaces were exposed to a potential hazardous atmosphere: (1) Flammable gas in excess of 10 percent of it's lower flammable limit (2) Atmospheric oxygen concentration below 19.5 percent.
Recent events (3)
  • — F (S) $0
  • — C (S) $4950
  • — Z (S) $4950

1910.146 C04

Other-than-serious 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.146(c)(4): If the employer decides that its employees will enter permit spaces, the employer shall develop and implement a written permit space program that complies with this section. The written program shall be available for inspection by employees and their authorized representatives:  On or about August 4, 2014, in the facility, employees performing batch plant and maintenance operations were required to enter permit spaces, including, but not limited to, the Batch Plant Drive-Over Pit and Cement Mixer, for cleaning and maintenance.  The employer did not develop a written permit space program that complied with this section in that the employer's written confined space entry program did not contain specific written procedures for each type of permit space entered.
Recent events (3)
  • — F (O) $0
  • — C (O) $0
  • — Z (O) $0

1910.1200 F06 I

Other-than-serious 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.1200(f)(6)(i): Except as provided in paragraphs (f)(7) and (f)(8) of this section, the employer shall ensure that each container of hazardous chemicals in the workplace is labeled , tagged or marked with the information specified under paragraphs (f)(1)(i) through (v) of this section:  On or about August 4, 2014, Dukane Precast Incorporated did not ensure that each container of hazardous chemicals in the Batch Plant was labeled, tagged or marked with the required information. Containers of hazardous chemicals not labeled, tagged or marked with required information included:  a)  Control Room: 5-gallon orange bucket containing SIKA 6100 Retarder b)  Floor: Chemical tote labeled with "3"
Recent events (3)
  • — F (O) $0
  • — C (O) $0
  • — Z (O) $0

View DUKANE PRECAST INCORPORATED's full OSHA safety record →