PECOS, TX ·
OSHA Inspection: LATSHAW DRILLING COMPANY, LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of LATSHAW DRILLING COMPANY, LLC in WOLFBONE (TREND AREA) FIELD, DUIKER STATE UNIT 14E LEASE, WELL #2H, LATSHAW RIG #11,30 MILES SE FROM PECOS, PECOS, TX 79772 (NAICS 213111). OSHA activity number 339891988.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- LATSHAW DRILLING COMPANY, LLC
- Site address
- WOLFBONE (TREND AREA) FIELD, DUIKER STATE UNIT 14E LEASE, WELL #2H, LATSHAW RIG #11,30 MILES SE FROM PECOS
- City
- PECOS
- State
- TX
- ZIP
- 79772
- Mailing
- P.O. BOX 691017, TULSA, OK 74169
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 213111
- Employees
- 1015
- Ownership type
- Private (A)
Citations
5 citations on file for this inspection.
1910.23 A05
- Issued
- Jan 7, 2015
- Abate by
- Jan 13, 2015
- Penalty
- Initial $4,250 · Current $0 Reduced
General-duty citation text
29 CFR 1910.23(a)(5): Every pit and floor opening was not adequately guarded by standard railing or any other effected means: Drill site: On or about August 6, 2014, the cellar pit located under Rig #11 was not covered. This condition exposed the employees to a fall hazard greater than 4-feet.
Recent events (3)
- · J (S) $0
- · C (S) $4250
- · Z (S) $4250
1910.132 D01 I
- Issued
- Jan 7, 2015
- Abate by
- Jan 13, 2015
- Penalty
- Initial $2,550 · Current $0 Reduced
General-duty citation text
29 CFR 1910.132(d)(1)(i): The employer did not select and have each affected employee use, the types of personal protective equipment that would protect the affected employee(s) from the hazards identified in the hazard assessment: Drill site: On or about August 6, 2014, and at times prior thereto, the employee mixing mud at the hopper was not wearing the proper eye protection (safety goggles). This condition exposed the employee to potential eye damage
Recent events (3)
- · J (S) $0
- · C (S) $2550
- · Z (S) $2550
1910.212 A01
- Issued
- Jan 7, 2015
- Abate by
- Jan 13, 2015
- Penalty
- Initial $2,550 · Current $2,550
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: On or about August 6, 2014, and at times prior thereto, the pedestal guards from the bench grinder located in the parts house were missing. This condition exposed the employees to a stuck-by hazard.
Recent events (3)
- · J (O) $2550
- · C (S) $2550
- · Z (S) $2550
1910.303 B07 I
- Issued
- Jan 7, 2015
- Abate by
- Jan 14, 2015
- Penalty
- Initial $4,250 · Current $0 Reduced
General-duty citation text
29 CFR 1910.303(b)(7)(i): Unused openings in boxes, raceways, auxiliary gutters, cabinets, equipment cases, or housings were not effectively closed to afford protection substantially equivalent to the wall of the equipment. On or about August 6, 2014, and at times prior thereto, an electrical breaker box located at the end of the crew living trailer was missing a knockout. This condition exposed the employees to an electrical hazard.
Recent events (3)
- · J (S) $0
- · C (S) $4250
- · Z (S) $4250
1910.303 B08 III
- Issued
- Jan 7, 2015
- Abate by
- Jan 20, 2015
- Penalty
- Initial $2,550 · Current $2,550
General-duty citation text
29 CFR 1910.303(b)(8)(iii): Electric equipment provided with ventilating openings was installed so that walls or other obstructions prevent the free circulation of air through the equipment: On or about August 6, 2014, and at times prior thereto, the electrical transformer located on left side of doorway of Rig Manager trailer was positioned close to the wall impeding air circulation. This condition exposed the employees to a fire hazard.
Recent events (3)
- · J (O) $2550
- · C (S) $2550
- · Z (S) $2550
More inspections at Latshaw Drilling Company, LLC
View Latshaw Drilling Company, LLC's full OSHA safety record →
More inspections in this industry (NAICS 213111)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339891988.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.