MINDEN, NV —
OSHA Inspection: NATIONAL FOREST SERVICE
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of NATIONAL FOREST SERVICE in 2311 FIREBRAND CIRCLE, MINDEN, NV 89423 (NAICS 813312). OSHA activity number 339896714.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- NATIONAL FOREST SERVICE
- Site address
- 2311 FIREBRAND CIRCLE
- City
- MINDEN
- State
- NV
- ZIP
- 89423
- Mailing
- 2311 FIREBRAND CIRCLE, MINDEN, NV 89423
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 813312
- Employees
- 20
- Ownership type
- D
Citations
4 citations on file for this inspection.
1910.303 B01
- Issued
- Sep 22, 2014
- Abate by
- Oct 16, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(b)(1): 29 CFR 1910.303(b)(1): Electrical equipment was not free from recognized hazards that were likely to cause death or serious physical harm to employees. (a) At the Sierra Front Inter Agency Dispatch Center Sleeping quarters room, an energized duplex convenience outlet receptacle located approximately four feet above the sink did not have a cover plate.
Recent events (1)
- — Z (S) $0
1910.304 B03 I
- Issued
- Sep 22, 2014
- Abate by
- Oct 16, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.304(b)(3)(i): All 125-volt, single-phase, 15- and 20-ampere receptacles installed in wet locations were not equipped with ground-fault circuit-interrupter protection for personnel. (a) At the Sierra Front Inter Agency Dispatch Center Sleeping quarters room, the duplex convenience outlet receptacle located approximately four feet above the sink did not have ground fault circuit interrupter protection for employees.
Recent events (1)
- — Z (S) $0
1910.22 B01
- Issued
- Sep 22, 2014
- Abate by
- Oct 16, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.22(b)(1): Aisles and passageways were not kept clear and in good repair, with no obstruction across or in aisles that could create a hazard. (a) At the employees office area, room 1451, a LAN/DATA cables were laying across an aisle way and creating trip hazards.
Recent events (1)
- — Z (O) $0
1910.157 C01
- Issued
- Sep 22, 2014
- Abate by
- Oct 16, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries. (a) At the Sierra Front Inter Agency Dispatch Center Lounge/Break room, a large trash can was sitting in front of the portable fire extinguisher.
Recent events (1)
- — Z (O) $0
More inspections at National Forest Service
View National Forest Service's full OSHA safety record →
More inspections in this industry (NAICS 813312)
More inspections in NV
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339896714.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.