BROOKLYN, NY ·
OSHA Inspection: BA TAMPTE PICKLE PRODUCTS INC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of BA TAMPTE PICKLE PRODUCTS INC in 77 BROOKLYN TERMINAL MARKET, BROOKLYN, NY 11236 (NAICS 311421). OSHA activity number 339898181.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- BA TAMPTE PICKLE PRODUCTS INC
- Site address
- 77 BROOKLYN TERMINAL MARKET
- City
- BROOKLYN
- State
- NY
- ZIP
- 11236
- Mailing
- 77 BROOKLYN TERMINAL MARKET, BROOKLYN, NY 11236
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Union (A)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 311421
- Employees
- 40
- Ownership type
- Private (A)
Citations
4 citations on file for this inspection.
1910.110 E04 III
- Issued
- Dec 18, 2014
- Abate by
- Dec 31, 2014
- Penalty
- Initial $2,800 · Current $3,825
General-duty citation text
29 CFR 1910.110(e)(4)(iii): Permanent and removable fuel containers were not securely mounted to prevent jarring loose, slipping, or rotating: a) Hyster 550 Powered Industrial Truck : On or about August 13, 2014 The Hyster did not have the mounting pin to facilitate secure mounting of fuel container.
Recent events (2)
- · I (S) $3825
- · Z (S) $2800
1910.178 P01
- Issued
- Dec 18, 2014
- Abate by
- Dec 31, 2014
- Penalty
- Initial $4,200 · Current $0 Reduced
General-duty citation text
29 CFR 1910.178(p)(1): Powered industrial truck(s) found to be in need of repair, defective, or in any way unsafe had not been taken out of service until restored to safe operating condition(s) a) Hyster 550 Powered Industrial Truck : On or about August 13, 2014 The Hyster had a broken clamp assembly but was not taken out of service.
Recent events (2)
- · I (S) $0
- · Z (S) $4200
1910.304 G05
- Issued
- Dec 18, 2014
- Abate by
- Dec 31, 2014
- Penalty
- Initial $2,800 · Current $3,825
General-duty citation text
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective: a) Packing Area : On or about August 13, 2014 An employees used a Dayton fan which was plugged in to a wall outlet. The fan cord was missing the ground pin.
Recent events (2)
- · I (S) $3825
- · Z (S) $2800
1910.305 B01 II
- Issued
- Dec 18, 2014
- Abate by
- Dec 31, 2014
- Penalty
- Initial $3,500 · Current $0 Reduced
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: a) Wet Storage Area : On or about August 13, 2014 An panel box used for area lighting and the heater opening which were not effectively closed. Live parts were not protected.
Recent events (2)
- · I (S) $0
- · Z (S) $3500
More inspections at BA Tampte Pickle Products INC
View BA Tampte Pickle Products INC's full OSHA safety record →
More inspections in this industry (NAICS 311421)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339898181.