OSHA Inspection: SPIRIT & SANZONE DISTRIBUTORS CO., INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of SPIRIT & SANZONE DISTRIBUTORS CO., INC. in 6495 FLY ROAD, EAST SYRACUSE, NY 13057 (NAICS 424810). OSHA activity number 339899379.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Spirit & Sanzone Distributors CO., INC. — free Get an email when a new federal OSHA severe-injury report for Spirit & Sanzone Distributors CO., INC. is published. One employer, no account, unsubscribe in one click.
Site address
6495 FLY ROAD
City
EAST SYRACUSE
State
NY
ZIP
13057
Mailing
P.O. BOX 696, EAST SYRACUSE, NY 13057
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
424810
Employees
100
Ownership type
A

9 citations on file for this inspection.

1910.24 H

Serious Gravity 1 2 instances 2 exposed
Issued
Sep 22, 2014
Abate by
Oct 25, 2014
Penalty
Initial $2,100 · Current $1,575 Reduced
29 CFR 1910.24(h): Standard railings were not provided on the open sides of all exposed stairways and stair platforms:  a)  Back Dock, on or about 8/13/14:  Fixed stairway and stair platform with five risers outside the exit door was not provided with standard railings.  b)  Rail exit door, on or about 8/13/14:  A fixed stairway with four risers outside the exit door was not provided with standard railings on the left side descending.  Abatement certification must be submitted for these items.
Recent events (2)
  • — I (S) $1575
  • — Z (S) $2100

1910.37 A03

Serious Gravity 1 1 instance 2 exposed
Issued
Sep 22, 2014
Abate by
Oct 2, 2014
Penalty
Initial $2,100 · Current $1,575 Reduced
29 CFR 1910.37(a)(3): Exit route(s) were not kept free and unobstructed:  a)  Cooler, on or about 8/13/14:  Exit door was blocked by pallets of kegs.  Abatement certification must be submitted for this item.
Recent events (2)
  • — I (S) $1575
  • — Z (S) $2100

1910.37 B04

Serious Gravity 1 2 instances 20 exposed
Issued
Sep 22, 2014
Abate by
Oct 25, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.37(b)(4): Signs were not posted along the exit access indicating the direction of travel to the nearest exit and exit discharge when the direction of travel to the exit or exit discharge was not immediately apparent:  a)  Back Dock Storage Area, on or about 8/13/14:  There were no exit directional signs to indicate the direction of travel to the nearest exit.  b)  Back Warehouse, on or about 8/13/14:  There were no exit directional signs to indicate the direction of travel to the nearest exit.  Abatement certification must be submitted for these items.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.304 G05

Serious Gravity 1 1 instance 1 exposed
Issued
Sep 22, 2014
Abate by
Oct 2, 2014
Penalty
Initial $2,100 · Current $1,575 Reduced
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective:  a)  Back Rail Dock, on or about 8/13/14:  An extension cord providing current to a pallet jack for charging it was not grounded, in that the ground pin was missing from the plug end.  Abatement certification must be submitted for this item.
Recent events (2)
  • — I (S) $1575
  • — Z (S) $2100

1910.305 G01 IV A

Serious Gravity 1 2 instances 2 exposed
Issued
Sep 22, 2014
Abate by
Oct 25, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:  a)  Can Densifier Area, on or about 8/13/14:  Extension cord providing current to a blower on the work platform for the Mosley can densiifier was tie wrapped along the frame of the machine and being used as permanent wiring.  b)  Can Densifier Area, on or about 8/13/14:  Extension cord providing current to the conveyor for the Mosley can densifier was being used as permanent wiring.  Abatement certification must be submitted for these items.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.157 G02

Repeat Gravity 1 1 instance 80 exposed
Issued
Sep 22, 2014
Abate by
Oct 25, 2014
Penalty
Initial $4,200 · Current $3,150 Reduced
29 CFR 1910.157(g)(2): The educational program to familiarize employees with the general principles of fire extinguisher use and the hazards involved with incipient stage fire fighting was not provided to all employees upon initial employment, and at least annually thereafter:  a)  At the establishment, on or about 8/13/14:  Annual training was not provided to employees on the use of fire extinguishers and the hazards involved with incipient stage fire fighting.  Training was last conducted 12/7/11.  *ABATEMENT NOTE:  By this date the employer must either correct the alleged violation or implement a Fire Safety Policy as outlined in 29 CFR 1910.38 and 29 1910.39 which includes the evacuation requirements of 29 CFR 1910.157(b).  Abatement documentation must be submitted for this item.  Spirit and Sanzone Distributors Co., Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard which was contained in OSHA inspection number 312374085, citation number 1, item number 2 and was affirmed as a final order on 3/30/10, with respect to a workplace located at 6495 Fly Road, East Syracuse, NY 13057.
Recent events (2)
  • — I (R) $3150
  • — Z (R) $4200

1910.212 A01

Serious Gravity 5 2 instances 2 exposed
Issued
Sep 22, 2014
Abate by
Oct 25, 2014
Penalty
Initial $7,000 · Current $5,250 Reduced
29 CFR 1910.212(a)(1): Machine guarding was not provided to protect operator(s) and other employees from hazard(s) created by ingoing nip points and rotating parts:    a)  Warehouse, on or about 8/13/14:  Ingoing nip points were not guarded on a Maren baler in that the interlocks were not functioning on the safety door.    b)  Maintenance Dept., on or about 8/13/14:  Rotating chuck on a Sears Craftsman drill press was not guarded.    Abatement documentation must be submitted for these items.      Spirit & Sanzone Distributors Co., Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard, which was contained in OSHA inspection number 312374085, citation number 1, item number 3 and was affirmed as a final order on 3/30/2010, with respect to a workplace located at 6495 Fly Road, East Syracuse, NY 13057.
Recent events (2)
  • — I (S) $5250
  • — Z (R) $7000

1910.22 A01

Other-than-serious 2 instances 2 exposed
Issued
Sep 22, 2014
Abate by
Oct 2, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms or service rooms were not kept clean and orderly or in a sanitary condition:  a)  Rail exit door, on or about 8/13/14:  Passageway down a fixed stairway outside the exit door was not maintained clear of vegetation.  b)  Can Densifier Area, on or about 8/13/14:  Passageways and work platforms in and around the can densifiers were not maintained clear of aluminum cans scattered throughout.    Abatement certification must be submitted for these items.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.22 A02

Other-than-serious 1 instance 2 exposed
Issued
Sep 22, 2014
Abate by
Oct 2, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.22(a)(2): Floor(s) of workroom(s) were not maintained in a clean and, so far as possible, a dry condition:  a)  Cooler, on or about 8/13/14:  Water was puddled on the floor in front of pallets of kegs from condensation.  Abatement certification must be submitted for this item.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Spirit & Sanzone Distributors CO., INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339899379.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.