OSHA Inspection: NEVADA AIR NATIONAL GUARD

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of NEVADA AIR NATIONAL GUARD in 1776 NATIONAL GUARD WAY BLDG 9, RENO, NV 89502 (NAICS 928110). OSHA activity number 339901829.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Nevada AIR National Guard for free Get an email when a new federal OSHA severe-injury report for Nevada AIR National Guard is published. One employer, no account, unsubscribe in one click.
Site address
1776 NATIONAL GUARD WAY BLDG 9
City
RENO
State
NV
ZIP
89502
Mailing
1776 NATIONAL GUARD WAY, RENO, NV 89502
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Union (A)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
928110
Employees
198
Ownership type
Federal government (D)

4 citations on file for this inspection.

1910.37 B05

Serious Gravity 1 2 instances 4 exposed
Issued
Aug 29, 2014
Abate by
Sep 24, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.37(b)(5): Each doorway or passage along an exit access that could be mistaken for an exit was not marked "Not an Exit" or similar designation, or be identified by a sign indicating its actual use (e.g. closet).  (a) At the metal tech's room 150 and at the solvent tank room 104, doors leading to the to the ISO break room, hydraulic and tire shop were not labeled not an exit.
Recent events (1)
  • · Z (S) $0

1910.212 A05

Serious Gravity 5 1 instance 1 exposed
Issued
Aug 29, 2014
Abate by
Sep 24, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.212(a)(5): Fan blade guards, where the periphery of the blades was less than seven feet above the floor or working level, had openings larger than one half inch.  (a) At the fabrication section room 124, the fan blade guard of the Emerson electric fan used for air circulation, had more than one half inch openings.
Recent events (1)
  • · Z (S) $0

1910.303 B01

Serious Gravity 5 1 instance 2 exposed
Issued
Aug 29, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.303(b)(1): Electrical equipment was not free from recognized hazards that were likely to cause death or serious physical harm to employees.  (a) At the metal tech shop room 138, the vertical band saw's lamp holder had a missing light bulb.
Recent events (1)
  • · Z (S) $0

1910.303 B02

Serious Gravity 5 1 instance 1 exposed
Issued
Aug 29, 2014
Abate by
Sep 24, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling.  (a) At the fabrication section room 124, a re-locatable power tap was used to extend power to the Igloo refrigerator, Black and Decker coffee maker and computer equipment.
Recent events (1)
  • · Z (S) $0

View Nevada AIR National Guard's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339901829.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.