BRILLION, WI —
OSHA Inspection: PROFESSIONAL PLATING INC
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of PROFESSIONAL PLATING INC in 705 NORTHWAY DRIVE, BRILLION, WI 54110 (NAICS 332812). OSHA activity number 339913758.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PROFESSIONAL PLATING INC
- Site address
- 705 NORTHWAY DRIVE
- City
- BRILLION
- State
- WI
- ZIP
- 54110
- Mailing
- 705 NORTHWAY DRIVE, BRILLION, WI 54110
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332812
- Employees
- 185
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.134 C01
- Issued
- Nov 6, 2014
- Abate by
- Dec 24, 2014
- Penalty
- Initial $2,971 · Current $1,000 Reduced
General-duty citation text
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use: a) On or about 09/17/2014, the employer's written respiratory protection program did not include the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) when Powder Coat Painter employees and Ceramic Painter employees were required to wear positive pressure air hood respirators and tight-fitting half-face respirators, respectively. All provisions of 29 CFR 1910.134(c) through (l) must be covered in a written respiratory protection program. Key elements include, but are not limited to, the following: 1) Respirator selection 2) Medical evaluations 3) Fit testing 4) Procedures for use, care and maintenance 5) Employee information and training 6) Program evaluation
Recent events (2)
- — I (O) $1000
- — Z (S) $2971
1910.134 E01
- Issued
- Nov 6, 2014
- Abate by
- Dec 24, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: a) On or about 09/17/2014, the employer did not provide Powder Coat Painter employees with medical evaluations to determine their ability to use positive pressure air hood respirators.
Recent events (2)
- — I (O) $0
- — Z (S) $0
More inspections at Professional Plating INC
View Professional Plating INC's full OSHA safety record →
More inspections in this industry (NAICS 332812)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339913758.