DALTON, GA ·
OSHA Inspection: C&H SERVICES OF NORTH GEORGIA, LLC.
Unprogrammed Related inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Related safety inspection of C&H SERVICES OF NORTH GEORGIA, LLC. in 1502 CORONET DRIVE, DALTON, GA 30720 (NAICS 811310). OSHA activity number 339926248.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- C&H SERVICES OF NORTH GEORGIA, LLC.
- Site address
- 1502 CORONET DRIVE
- City
- DALTON
- State
- GA
- ZIP
- 30720
- Mailing
- 1015 NEW SOUTH HARRIS ST., DALTON, GA 30721
What kind of inspection was it?
- Inspection type
- Unprogrammed Related (G)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 811310
- Employees
- 75
- Ownership type
- Private (A)
Citations
5 citations on file for this inspection.
1910.146 C09 I
- Issued
- Dec 4, 2014
- Abate by
- Dec 31, 2014
- Penalty
- Initial $5,390 · Current $0 Reduced
General-duty citation text
29 CFR 1910.146(c)(9)(i): Each contractor who was retained to perform permit space entry operations did not obtain any available information regarding permit space hazards and entry operations from the host employer: a. 1510 Coronet Drive, Dalton GA - The entry contractor did not obtain all relevant information necessary for their employee's safety, prior to entering the permit confined space in mixing tank D.
Recent events (2)
- · I (S) $0
- · Z (S) $5390
1910.146 D03
- Issued
- Dec 4, 2014
- Abate by
- Dec 31, 2014
- Penalty
- Initial $5,390 · Current $0 Reduced
General-duty citation text
29 CFR 1910.146(d)(3): Under the permit-required confined space program required by 29 CFR 1910.146(c)(4), the employer did not develop and implement the means, procedures, and practices necessary for safe permit space entry operations: a. 1510 Coronet Drive, Dalton GA - The company did not develop and implement a means or procedure, to control all potential hazards prior to entering the permit required confined space in mixing tank D, thereby exposing the employee to hazards such as but not limited to falls, noise, potential hazardous energy release, moving mechanical parts, engulfment and drowning.
Recent events (2)
- · I (S) $0
- · Z (S) $5390
1910.146 F08
- Issued
- Dec 4, 2014
- Abate by
- Dec 31, 2014
- Penalty
- Initial $5,390 · Current $0 Reduced
General-duty citation text
29 CFR 1910.146(f)(8): The entry permit that documented compliance and authorized entry to a permit space did not identify the measures used to isolate the permit space and to eliminate or control permit space hazards before entry: a. 1510 Coronet Drive, Dalton GA - The entry permit did not document the authorized ways used to isolate and eliminate the hazards associated with drowning and potentially hazardous energy sources prior to sending employees to work in the permit required confined space in mixing tank D.
Recent events (2)
- · I (S) $0
- · Z (S) $5390
1910.147 C04 I
- Issued
- Dec 4, 2014
- Penalty
- Initial $5,390 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: a. 1510 Coronet Drive, Dalton GA - The employer did not develop, document and use a hazardous energy control procedure prior to entering the permit required confined space for mixing tank D.
Recent events (2)
- · I (S) $0
- · Z (S) $5390
1910.147 D03
- Issued
- Dec 4, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment was not physically located and operated in such a manner as to isolate the machine or equipment from the energy source: a. 1510 Coronet Drive, Dalton GA - When employees entered the permit required confined space, all controls for potentially hazardous energy were not operated in a manner as to isolate mixing tank D's equipment from all hazardous energy sources.
Recent events (2)
- · I (S) $0
- · Z (S) $0
More inspections at C&H Services of North Georgia, LLC.
View C&H Services of North Georgia, LLC.'s full OSHA safety record →
More inspections in this industry (NAICS 811310)
More inspections in GA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339926248.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.