OSHA Inspection: C&H SERVICES OF NORTH GEORGIA, LLC.

Unprogrammed Related inspection · Safety discipline

On , OSHA opened an unprogrammed Related safety inspection of C&H SERVICES OF NORTH GEORGIA, LLC. in 1502 CORONET DRIVE, DALTON, GA 30720 (NAICS 811310). OSHA activity number 339926248.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch C&H Services of North Georgia, LLC. for free Get an email when a new federal OSHA severe-injury report for C&H Services of North Georgia, LLC. is published. One employer, no account, unsubscribe in one click.
Site address
1502 CORONET DRIVE
City
DALTON
State
GA
ZIP
30720
Mailing
1015 NEW SOUTH HARRIS ST., DALTON, GA 30721
Inspection type
Unprogrammed Related (G)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
811310
Employees
75
Ownership type
Private (A)

5 citations on file for this inspection.

1910.146 C09 I

Deleted Serious Gravity 10 1 instance 5 exposed
Issued
Dec 4, 2014
Abate by
Dec 31, 2014
Penalty
Initial $5,390 · Current $0 Reduced
29 CFR 1910.146(c)(9)(i): Each contractor who was retained to perform permit space entry operations did not obtain any available information regarding permit space hazards and entry operations from the host employer:   a.  1510 Coronet Drive, Dalton GA - The entry contractor did not obtain all relevant information necessary for their employee's safety, prior to entering the permit confined space in mixing tank D.
Recent events (2)
  • · I (S) $0
  • · Z (S) $5390

1910.146 D03

Deleted Serious Gravity 10 1 instance 5 exposed
Issued
Dec 4, 2014
Abate by
Dec 31, 2014
Penalty
Initial $5,390 · Current $0 Reduced
29 CFR 1910.146(d)(3): Under the permit-required confined space program required by 29 CFR 1910.146(c)(4), the employer did not develop and implement the means, procedures, and practices necessary for safe permit space entry operations:  a.  1510 Coronet Drive, Dalton GA - The company did not develop and implement a means or procedure, to control all potential hazards prior to entering the permit required confined space in mixing tank D, thereby exposing the employee to hazards such as but not limited to falls, noise, potential hazardous energy release, moving mechanical parts, engulfment and drowning.
Recent events (2)
  • · I (S) $0
  • · Z (S) $5390

1910.146 F08

Deleted Serious Gravity 10 1 instance 5 exposed
Issued
Dec 4, 2014
Abate by
Dec 31, 2014
Penalty
Initial $5,390 · Current $0 Reduced
29 CFR 1910.146(f)(8): The entry permit that documented compliance and authorized entry to a permit space did not identify the measures used to isolate the permit space and to eliminate or control permit space hazards before entry:  a.  1510 Coronet Drive, Dalton GA - The entry permit did not document the authorized ways used to isolate and eliminate the hazards associated with drowning and potentially hazardous energy sources prior to sending employees to work in the permit required confined space in mixing tank D.
Recent events (2)
  • · I (S) $0
  • · Z (S) $5390

1910.147 C04 I

Deleted Serious Gravity 10 1 instance 5 exposed
Issued
Dec 4, 2014
Penalty
Initial $5,390 · Current $0 Reduced
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:  a.  1510 Coronet Drive, Dalton GA - The employer did not develop, document and use a hazardous energy control procedure prior to entering the permit required confined space for mixing tank D.
Recent events (2)
  • · I (S) $0
  • · Z (S) $5390

1910.147 D03

Deleted Serious Gravity 10 1 instance 5 exposed
Issued
Dec 4, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment was not physically located and operated in such a manner as to isolate the machine or equipment from the energy source:   a.  1510 Coronet Drive, Dalton GA - When employees entered the permit required confined space, all controls for potentially hazardous energy were not operated in a manner as to isolate mixing tank D's equipment from all hazardous energy sources.