VON ORMY, TX ·
OSHA Inspection: A-1 METAL FINISHING & POLISHING
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of A-1 METAL FINISHING & POLISHING in 22831 HWY. 16, VON ORMY, TX 78073 (NAICS 332813). OSHA activity number 339929739.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- A-1 METAL FINISHING & POLISHING
- Site address
- 22831 HWY. 16
- City
- VON ORMY
- State
- TX
- ZIP
- 78073
- Mailing
- 22831 HWY. 16, VON ORMY, TX 78073
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332813
- Employees
- 5
- Ownership type
- Private (A)
Citations
6 citations on file for this inspection.
1910.215 A01
- Issued
- Oct 3, 2014
- Abate by
- Oct 13, 2014
- Penalty
- Initial $1,600 · Current $800 Reduced
General-duty citation text
29 CFR 1910.215(a)(1): Abrasive wheel(s) used on grinding machinery were not used with safety guard(s): Polishing area, On or about August 07, 2014, employees were exposed to a stuck-by hazard while operating an Ohas Hommedie & Sons Company stationary grinder that lack guards around the grinding wheel and spindle nut.
Recent events (2)
- · I (S) $800
- · Z (S) $1600
1910.219 D01
- Issued
- Oct 3, 2014
- Abate by
- Oct 13, 2014
- Penalty
- Initial $1,600 · Current $800 Reduced
General-duty citation text
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o): Polishing area, On or about August 07, 2014, employees were exposed to a caught-in hazard while working near the Ohas Hommedie & Sons Company stationary grinder which lacked a guard around the rotating pulley of the power transmission system.
Recent events (2)
- · I (S) $800
- · Z (S) $1600
1910.219 E01 I
- Issued
- Oct 3, 2014
- Abate by
- Oct 13, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.219(e)(1)(i): Horizontal belts which had both runs 42 inches or less from the floor level were not fully enclosed by guards conforming to requirements specified in 29 CFR 1910.219(m) and (o): Polishing area, On or about August 07, 2014, employees were exposed to a caught-in hazard while working near the Ohas Hommedie & Sons Company stationary grinder which lacked a guard around the rotating belts of the power transmission system.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.242 B
- Issued
- Oct 3, 2014
- Abate by
- Oct 9, 2014
- Penalty
- Initial $1,600 · Current $800 Reduced
General-duty citation text
29 CFR 1910.242(b): Compressed air used for cleaning. Compressed air shall not be used for cleaning purposes except where reduced to less than 30 p.s.i. and then only with effective chip guarding and personal protective equipment. Polishing area, On or about August 07, 2014, employees were exposed to a struck-by hazard while operating a compressed air blow off gun, to clean parts and person, while the compressed air pressure was not reduced below 30 p.s.i.
Recent events (2)
- · I (S) $800
- · Z (S) $1600
1910.303 B01
- Issued
- Oct 3, 2014
- Abate by
- Oct 13, 2014
- Penalty
- Initial $2,400 · Current $1,200 Reduced
General-duty citation text
29 CFR 1910.303(b)(1): Electrical equipment was not free from recognized hazards that were likely to cause death or serious physical harm to employees: a) Next to Chrome bath, On or about August 07, 2014, employees were exposed to an electrical hazard while working near the Dynapower Power Conversion System which had a flexible conduit, which supplied electricity to the unit, which was disconnected from the connector, thus exposing the internal wiring within the conduit. b) Above the bench, Polishing cleaning area, On or about August 07, 2014, employees were exposed to an electrical hazard while working near the Quad 120 Volt AC Receptacle which had a flexible conduit which was not continuous thus exposing the internal wiring within the conduit. c) Nickel bath area, On or about August 07, 2014, employees were exposed to an electrical hazard while working near the Nickel bath tank, which had an electrical junction not contained within a junction box, thus exposing employees to the 120 Volt AC wiring nut junction. d) Nickel bath area, On or about August 07, 2014, employees were exposed to an electrical hazard while working near the Nickel bath tank, which had a flexible conduit, supplying electricity to the bath heater, that was disconnected from the connector thus exposing the internal 120 Volt AC wiring within the conduit.
Recent events (2)
- · I (S) $1200
- · Z (S) $2400
1910.305 B01
- Issued
- Oct 3, 2014
- Abate by
- Oct 13, 2014
- Penalty
- Initial $1,600 · Current $800 Reduced
General-duty citation text
29 CFR 1910.305(b)(1): Unused openings in boxes, cabinets, or fittings were not effectively closed: a) Stationary Polisher #1 (Left), On or about August 07, 2014, employees were using the polisher while the electrical cabinet had an approximately 1" x 5" rectangular opening exposing employees to the internal 120 volt AC wiring. b) Next to Chrome bath, On or about August 07, 2014, employees were exposed to an electrical hazard while working near the DC Power Supply which had missing knockouts thus exposing the power supplies internal wiring. c) Above the bench, Polishing cleaning area, On or about August 07, 2014, employees were exposed to an electrical hazard while working near the Quad 120 Volt AC Receptacle which had a missing knockout. d) Chemical bath area, break room wall, , On or about August 07, 2014, employees were exposed to an electrical hazard while working near the rinse tank, which had an electrical disconnect providing electricity that had a missing knockout thus exposing employees to the disconnects internal 240 Volt AC wiring. e) Chemical bath area, break room wall, , On or about August 07, 2014, employees were exposed to an electrical hazard while working near the circuit breaker panel "D" which had a missing circuit breaker knockout, thus exposing employees to the 240 Volt AC bus bar.
Recent events (2)
- · I (S) $800
- · Z (S) $1600
More inspections at A-1 Metal Finishing & Polishing
View A-1 Metal Finishing & Polishing's full OSHA safety record →
More inspections in this industry (NAICS 332813)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339929739.