SANBORN, NY —
OSHA Inspection: VOSS MANUFACTURING, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of VOSS MANUFACTURING, INC. in 2345 LOCKPORT ROAD, SANBORN, NY 14132 (NAICS 333517). OSHA activity number 339933459.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- VOSS MANUFACTURING, INC.
- Site address
- 2345 LOCKPORT ROAD
- City
- SANBORN
- State
- NY
- ZIP
- 14132
- Mailing
- 2345 LOCKPORT ROAD, SANBORN, NY 14132
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 333517
- Employees
- 91
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.217 B06 I
- Issued
- Sep 22, 2014
- Abate by
- Oct 15, 2014
- Penalty
- Initial $2,975 · Current $2,231 Reduced
General-duty citation text
29 CFR 1910.217(b)(6)(i): Two-hand trip(s) on mechanical power press(es) using full revolution clutches did not have the individual operator's hand controls arranged by design and construction to use a control arrangement requiring concurrent operation of the individual operator's hand controls: a) On or about 09/04/2014 in the press area; where the two hand trips on the Niagara A-18 full revolution, mechanical power press (serial no.43621) did not require both trips to be released before initiating a successive stroke of the press. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $2231.25
- — Z (S) $2975
1910.217 E01 I
- Issued
- Sep 22, 2014
- Abate by
- Oct 15, 2014
- Penalty
- Initial $2,975 · Current $2,231 Reduced
General-duty citation text
29 CFR 1910.217(e)(1)(i): A program of periodic and regular inspections of mechanical power press(es) was not established and followed to ensure that all parts, auxiliary equipment and safeguards were in a safe operating condition and adjustment: a) On or about 09/04/2014 in the press area; where the employer operates both full revolution and part revolution mechanical power presses for production. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $2231.25
- — Z (S) $2975
1910.253 B04 III
- Issued
- Sep 22, 2014
- Abate by
- Oct 15, 2014
- Penalty
- Initial $1,785 · Current $1,339 Reduced
General-duty citation text
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour: a) On or about 09/04/2014 in the weld area; where oxygen and acetylene cylinders were stored next to each other in the cylinder storage area. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $1338.75
- — Z (S) $1785
1910.147 C06 II
- Issued
- Sep 22, 2014
- Abate by
- Oct 15, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(6)(ii): The employer did not certify that the periodic inspections of employees performing energy control procedures had been performed. (The certification shall identify the machine or equipment on which the energy control procedure was being utilized, the date of the inspection, the employees included in the inspection, and the person performing the inspection.): a) On or about 09/04/2014 in the protection areas; where the employer did not certify periodic inspections of employees performing "lockout" procedures. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.303 B02
- Issued
- Sep 22, 2014
- Abate by
- Oct 15, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: a) On or about 09/04/2014 in the sheet metal/laser department; where a metal duplex receptacle box was used at the end of a flexible cord as extension cord (not secured in place as per the National Electrical Code). ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Voss Manufacturing, INC.
View Voss Manufacturing, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 333517)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339933459.