SANBORN, NY —
OSHA Inspection: VOSS MANUFACTURING, INC.
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of VOSS MANUFACTURING, INC. in 2345 LOCKPORT ROAD, SANBORN, NY 14132 (NAICS 332710). OSHA activity number 346081003.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- VOSS MANUFACTURING, INC.
- Site address
- 2345 LOCKPORT ROAD
- City
- SANBORN
- State
- NY
- ZIP
- 14132
- Mailing
- 2345 LOCKPORT ROAD, SANBORN, NY 14132
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332710
- Employees
- 115
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.95 C01
- Issued
- Aug 18, 2022
- Abate by
- Oct 5, 2022
- Penalty
- Initial $13,052 · Current $9,789 Reduced
8110
General-duty citation text
29 CFR 1910.95(c)(1):The employer did not administer a continuing, effective hearing conservation program as described in 29 CFR 1910.9(c) through (o) whenever employee noise exposures equal or exceed an 8-hour time-weighted average sound level of 85 decibels measured on the A scale, or equivalently a dose of fifty percent: a) Plant - On or about 07/28/22, employees working in the prep area were exposed to continuous noise level at 73.3% of the permissible daily noise level (8 hour time-weighed average sound level of 90 dBA) or equivalent time-weighted of approximately 90.5 dBA during the 331 minute sampling period on July 28, 2022. Exposure calculations included 149 minutes not sampled. The employer has not instituted a hearing conservation program. A hearing conservation program should include descriptions of how the criteria for: 1. Are there areas in the workplace where continuous noise levels exceed 85 decibels?; 2. Is there an ongoing preventive health program to educate employees in safe levels of noise, exposures, effects of noise on their health and the use of personal protection?; 3. Have engineering controls been used to reduce excessive noise levels? Where engineering controls are determined to be infeasible, are administrative control (i.e., worker rotation) being used to minimize individual employee exposure to noise?; 4. Is approved hearing protective equipment (noise attenuating devices) available to every employee working in noisy areas?; 5. Have you tried isolating noisy machinery from the rest of your operation? 6. If employees use ear protectors, are employees properly fitted and instructed in their use?; AND 7. The general requirements of this section. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $9789
- — Z (S) $13052
1910.134 C
- Issued
- Aug 18, 2022
- Abate by
- Oct 5, 2022
- Penalty
- Initial $7,458 · Current $5,594 Reduced
General-duty citation text
29 CFR 1910.134(c): The employer did not develop and implement a written respiratory protection program with required worksite-specific procedures and elements for required respirator use: a) Plant - On or about and prior to July 14, 2022 and ongoing, employees required and provided with 3M-7502 half-face respirator, with 3M-6001 particulate filters while working in the prep area. The employer did not develop and implement a written respiratory protection program with required worksite-specific procedures and elements for required respirator user. b) Plant - On or about and prior to July 14, 2022 and ongoing, employees required and provided with 3M-7502 half-face respirator, with P100-2097 particulate filters while working in the prep area. The employer did not develop and implement a written respiratory protection program with required worksite-specific procedures and elements for required respirator user. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $5593.5
- — Z (S) $7458
1910.134 E01
- Issued
- Aug 18, 2022
- Abate by
- Oct 5, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: a) Plant - On or about and prior to July 14, 2022 and ongoing, employees required and provided with 3M-7502 half-face respirator, with 3M-6001 particulate filters while working in the prep area. The employee was not provided with a medical evaluation to determine the employee's ability to use a respirator, prior to using the respirator. b) Plant - On or about and prior to July 14, 2022 and ongoing, employees required and provided with 3M-7502 half-face respirator, with P100-2097 particulate filters while working in the prep area. The employee was not provided with a medical evaluation to determine the employee's ability to use a respirator, prior to using the respirator. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.134 K
- Issued
- Aug 18, 2022
- Abate by
- Oct 5, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(k): The employer did not provide comprehensive, understandable training which did not occur annually and/or more often. a) Plant - On or about and prior to July 14, 2022 and ongoing, employees required and provided with 3M-7502 half-face respirator, with 3M-6001 with particulate filters while working in the prep area. The employer did not provide information and training to employees who worn respirator. b) Plant - On or about and prior to July 14, 2022 and ongoing, employees required and provided with 3M-7502 half-face respirator, with P100-2097 with particulate filters while working in the prep area. The employer did not provide information and training to employees who worn respirator. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Voss Manufacturing, INC.
View Voss Manufacturing, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 332710)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346081003.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.