Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,194,531Inspections Most recent open 2026-08-11 Last loaded 2026-08-14

OSHA Inspection: FERMIN LORENZO

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of FERMIN LORENZO in 5545 DOOLEY WAY SHILOH WOODS SUBDIVISION LOT #108, CUMMING, GA 30040 (NAICS 238130). OSHA activity number 339934572.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Fermin Lorenzo for free Get an email when a new federal OSHA severe-injury report for Fermin Lorenzo is published. One employer, no account, unsubscribe in one click.
Establishment
FERMIN LORENZO
Site address
5545 DOOLEY WAY SHILOH WOODS SUBDIVISION LOT #108
City
CUMMING
State
GA
ZIP
30040
Mailing
5935 HILLSIDE DR., ATLANTA, GA 30340
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
2
Ownership type
A

4 citations on file for this inspection.

1926.501 B13

Serious Gravity 5 1 instance 2 exposed
Issued
Sep 22, 2014
Abate by
Oct 2, 2014
Penalty
Initial $2,400 · Current $1,440 Reduced
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):   a) Site -  On or about 09/02/14 and at times prior thereto employees were installing the second floor joists  and were standing/walking on the top plate at 9.0 ft. above ground level without fall protection equipment.   In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition documentation demonstrating that abatement is complete must be included with your certification.
Recent events (2)
  • · I (S) $1440
  • · Z (S) $2400

1926.1053 B01

Serious Gravity 5 1 instance 2 exposed
Issued
Sep 22, 2014
Abate by
Oct 2, 2014
Penalty
Initial $1,600 · Current $960 Reduced
29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access:  a) Site -  On or about 09/02/14 and at times prior thereto employees were installing the second floor joists and climbed onto the top plate by use of a 6 ft. step ladder which did not extend 3.0 ft. above the top plate. (Gap between top step of ladder and top plate: 42 in.).    In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition documentation demonstrating that abatement is complete must be included with your certification.
Recent events (2)
  • · I (S) $960
  • · Z (S) $1600

1926.1053 B13

Serious Gravity 5 1 instance 2 exposed
Issued
Sep 22, 2014
Abate by
Oct 2, 2014
Penalty
Initial $0 · Current $0
29 CFR 1926.1053(b)(13): The top or top step of a stepladder was used as a step:  a) Site -  On or about 09/02/14 and at times prior thereto employees were installing the second floor joists and climbed onto the top plate by use of a 6 ft. step ladder which did not extend 3.0 ft. above the top plate.  Employees stood on the top step of the ladder to reach the top plate of the wall situated at a 10 ft. elevation from ground level. (The gap between the top step of the ladder and top plate of the wall was 42 in.).    In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition documentation demonstrating that abatement is complete must be included with your certification.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1926.1060 A01

Serious Gravity 5 1 instance 2 exposed
Issued
Sep 22, 2014
Abate by
Oct 2, 2014
Penalty
Initial $0 · Current $0
29 CFR 1926.1060(a)(1): 1926.1060(a)(1):  The employer did not ensure that each employee was trained by a competent person which would enable each employee to recognize hazards related to ladders and stairs, and the procedures to follow to minimize those hazards.  a) Site -  On or about 09/02/14 and at times prior thereto employees were installing the second floor joists and climbed onto the top plate by use of a 6 ft. step ladder which did not extend 3.0 ft. above the top plate.  Employees stood on the top step of the ladder to reach the top plate of the wall situated at a 10 ft. elevation from ground level. The employer did not ensure that employees were trained by a competent person in the safe use of ladders and in the recognition of the associated hazards.    In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition documentation demonstrating that abatement is complete must be included with your certification.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

View Fermin Lorenzo's full OSHA safety record →