WAYNESBORO, GA ·
OSHA Inspection: SAM DONG GEORGIA, INC.
Referral inspection · Health discipline
At a glance
On , OSHA opened a referral health inspection of SAM DONG GEORGIA, INC. in 770 MILLS RD, WAYNESBORO, GA 30830 (NAICS 331421). OSHA activity number 339946386.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SAM DONG GEORGIA, INC.
- Site address
- 770 MILLS RD
- City
- WAYNESBORO
- State
- GA
- ZIP
- 30830
- Mailing
- 770 MILLS RD, WAYNESBORO, GA 30830
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 331421
- Employees
- 94
- Ownership type
- Private (A)
Citations
5 citations on file for this inspection.
1910.132 A
- Issued
- Sep 30, 2014
- Abate by
- Oct 27, 2014
- Penalty
- Initial $4,250 · Current $2,550 Reduced
2260
General-duty citation text
29 CFR 1910.132(a): Protective equipment was not used when necessary whenever hazards capable of causing injury and impairment were encountered: (a) Quality Control Lab, on or about and at times preceding to September 9, 2014, protective equipment such as faceshield, chemical resistant apron, chemical resistant arm guards, and chemical resistant gloves were not provided and/or utilized when working with heated caustic soda.
Recent events (2)
- · I (S) $2550
- · Z (S) $4250
1910.151 C
- Issued
- Sep 30, 2014
- Abate by
- Oct 27, 2014
- Penalty
- Initial $4,250 · Current $2,550 Reduced
2260
General-duty citation text
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use: (a) Quality Control Lab, on or about and at times preceding to September 8, 2014, area where heated caustics are utilized in quality control process, an eyewash station/quick drench station station was not readily available.
Recent events (2)
- · I (S) $2550
- · Z (S) $4250
1910.1200 F05 II
- Issued
- Sep 30, 2014
- Abate by
- Oct 27, 2014
- Penalty
- Initial $3,400 · Current $2,040 Reduced
2260
General-duty citation text
29 CFR 1910.1200(f)(5)(ii): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the appropriate hazard warnings: (a) Quality Control Lab, on or about and at times preceding to July 6, 2014, heated caustic chemicals used in workplace were not identified as to contents or hazards.
Recent events (2)
- · I (S) $2040
- · Z (S) $3400
1910.1200 H01
- Issued
- Sep 30, 2014
- Abate by
- Oct 27, 2014
- Penalty
- Initial $0 · Current $0
2260
General-duty citation text
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: a) Quality Control Lab, on or about and at times preceding to September 9, 2014, employees were not provided effective information on the hazards of exposure to caustic soda.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.1200 H03 III
- Issued
- Sep 30, 2014
- Abate by
- Oct 27, 2014
- Penalty
- Initial $0 · Current $0
2260
General-duty citation text
29 CFR 1910.1200(h)(3)(iii): The measures employees can take to protect themselves from these hazards, including specific procedures the employer has implemented to protect employees from exposure to hazardous chemicals, such as appropriate work practices, emergency procedures, and personal protective equipment to be used; a) Quality Control Lab, employees using heated caustic soda were not informed as to the appropriate emergency procedures to be enacted in the event of a chemical splash. Employees were not informed to immediately flush burned area with water for 15 minutes.
Recent events (2)
- · I (S) $0
- · Z (S) $0
More inspections at SAM Dong Georgia, INC.
View SAM Dong Georgia, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 331421)
More inspections in GA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339946386.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.