MAUMELLE, AR ·
OSHA Inspection: BCCH LLC
Follow-up inspection · Safety discipline
At a glance
On , OSHA opened a follow-up safety inspection of BCCH LLC in 100 FOUR PAWS LANE, MAUMELLE, AR 72113 (NAICS 311111). OSHA activity number 339959777.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- BCCH LLC
- Site address
- 100 FOUR PAWS LANE
- City
- MAUMELLE
- State
- AR
- ZIP
- 72113
- Mailing
- 100 FOUR PAWS LANE, MAUMELLE, AR 72113
What kind of inspection was it?
- Inspection type
- Follow-up (F)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 311111
- Employees
- 75
- Ownership type
- A
Citations
1 citation on file for this inspection.
1910.334 A02 I
- Issued
- Sep 24, 2014
- Abate by
- Oct 2, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.334(a)(2)(i): Portable cord and plug connected equipment and flexible cord sets (extension cords) were not visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket): The employer does not ensure that all portable cord and plug connected equipment are inspected for defects/damage. This violation occurred on or about September 15, 2014, in the kitchen area where employees were using a rotary cookie machine that had a flexible electric cord that had been damaged and did not retained the insulation, outer sheath properties of the cord. Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the abatement date, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that portable and flexible cords are inspected for defects/damage.
Recent events (1)
- · Z (O) $0
More inspections at Bcch LLC
View Bcch LLC's full OSHA safety record →
More inspections in this industry (NAICS 311111)
More inspections in AR
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339959777.