DAYTON, OH ·
OSHA Inspection: U.S. DEPARTMENT OF VETERANS AFFAIRS #552
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of U.S. DEPARTMENT OF VETERANS AFFAIRS #552 in 4100 W. THIRD STREET, DAYTON, OH 45428 (NAICS 622110). OSHA activity number 339975443.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- U.S. DEPARTMENT OF VETERANS AFFAIRS #552
- Site address
- 4100 W. THIRD STREET
- City
- DAYTON
- State
- OH
- ZIP
- 45428
- Mailing
- 4100 W. THIRD STREET, MAIL STOP SOHS, DAYTON, OH 45428
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Union (A)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 622110
- Employees
- 2317
- Ownership type
- Federal government (D)
Citations
2 citations on file for this inspection.
1910.212 A01
- Issued
- Dec 19, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.212(a)(1): Types of guarding. One or more methods of machine guarding shall be provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks. Examples of guarding methods are-barrier guards, two-hand tripping devices, electronic safety devices, etc.: (a) The chuck on the Southern Bend Machine Lathe located in the Machine Shop, was not guarded. (b) The blade on the DoAll Vertical Band Saw located in the Machine Shop, was not adequately guarded in that there was 1 ½ inches of unguarded blade running through the guide rolls.
Recent events (1)
- · Z (S) $0
1910.147 C06 I
- Issued
- Dec 19, 2014
- Abate by
- Jan 16, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer shall conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed: (a) The periodic inspection of the energy control program was inadequate, in that it did not include having employees actually lock out a piece of equipment while being observed by an inspector.
Recent events (1)
- · Z (O) $0
More inspections at U.S. Department of Veterans Affairs #552