On , OSHA opened a planned health inspection of GEORGIA GUTTERS, INC. in 1014 SAMPLER WAY SUITE D, EAST POINT, GA 30344 (NAICS 332322). OSHA activity number 339976656.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Georgia Gutters, INC. — free Get an email when a new federal OSHA severe-injury report for Georgia Gutters, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1014 SAMPLER WAY SUITE D
City
EAST POINT
State
GA
ZIP
30344
Mailing
1014 SAMPLER WAY SUITE D, EAST POINT, GA 30344
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332322
Employees
13
Ownership type
A

7 citations on file for this inspection.

1910.1025 D02

Serious Gravity 5 1 instance 3 exposed
Issued
Jan 7, 2015
Abate by
Feb 3, 2015
Penalty
Initial $2,000 · Current $2,000

Hazardous substances BWPB

29 CFR 1910.1025(d)(2): An initial determination was not made to determine if any employee may be exposed to lead at or above the action level:  a) Soldering Area;  The employer required employees to perform soldering with a 50/50 lead-tin soldering bar without determining if employees were exposed to lead at or above the action level.
Recent events (3)
  • — I $5000
  • — Z $10000
  • — Z (S) $2000

1910.1025 H01

Serious Gravity 5 1 instance 3 exposed
Issued
Jan 7, 2015
Abate by
Feb 25, 2015
Penalty
Initial $2,000 · Current $2,000
29 CFR 1910.1025(h)(1): All surfaces were not maintained as free as practicable of accumulations of lead:  a) Production/Soldering Area:  The employer did not ensure that surfaces were maintained free of lead accumulations.  A wipe sample from the soldering work table was collected on October 28, 2014 revealing 340.2 micrograms of lead present.  b) Production/Soldering Area:  The employer did not ensure that surfaces were maintained free of lead accumulations.  A wipe sample from the soldering side work table was collected on October 28, 2014 revealing  22.1294 milligrams of lead present.  c) Production/Soldering Area:  The employer did not ensure that surfaces were maintained free of lead accumulations.  A wipe sample from the handle of the soldering tool was collected on October 28, 2014 revealing 33.6070 micrograms milligrams of lead present.  d) Production/Soldering Area:  The employer did not ensure that surfaces were maintained free of lead accumulations.  A wipe sample from the lunch/break table was collected on October 28, 2014 revealing 10.4220 micrograms of lead present.
Recent events (1)
  • — Z (S) $2000

1910.1025 L01 I

Serious Gravity 5 1 instance 3 exposed
Issued
Jan 7, 2015
Abate by
Feb 25, 2015
Penalty
Initial $2,000 · Current $2,000
29 CFR 1910.1025(l)(1)(i): Employee(s) working in an area where there is potential exposure to airborne lead at any level were not informed of the content of Appendices A and B of 29 CFR 1910.1025:  a) Production Area; Employees were required to work with 50/50 lead soldering bars while sealing gutter seams.  The employer did not provide training specific to the hazards of lead to all employees exposed to lead.  Exposure to lead could result in neurological damage and reproductive damage.
Recent events (3)
  • — I $5000
  • — Z $10000
  • — Z (S) $2000

1910.1200 E01

Serious Gravity 5 1 instance 13 exposed
Issued
Jan 7, 2015
Abate by
Feb 25, 2015
Penalty
Initial $1,600 · Current $1,600
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met:  a) Production Area; The employer had not established or implemented a written Hazard Communication program.  Employees were exposed to chemicals such as, but not limited to, 50/50 lead soldering bars,  propane gas, Ruby Fluid Soldering and Tinning Flux.  Exposure to lead could result in neurological damage and reproductive damage.  Exposure to propane gas could result in respiratory and skin irritation.
Recent events (3)
  • — I $5000
  • — Z $8000
  • — Z (S) $1600

1910.1200 H01

Serious Gravity 5 1 instance 13 exposed
Issued
Jan 7, 2015
Abate by
Feb 25, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area.  a) Production Area: Employees were required to work with chemicals such as, but not limited to, 50/50 lead soldering bars, Ruby Fluid Soldering and Tinning Flux, and propane gas. The employer did not provide training specific to the hazards of chemicals used at the establishment to all employees working with hazardous chemicals.  Exposure to lead could result in neurological damage and reproductive damage. Exposure to Ruby Fluid Soldering and Tinning Flux and propane gas could result in respiratory and skin irritation.
Recent events (3)
  • — I $0
  • — Z $0
  • — Z (S) $0

1910.38 A

Other-than-serious 1 instance 13 exposed
Issued
Jan 7, 2015
Abate by
Feb 3, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.38(a): The employer did not establish a written emergency evacuation plan for employees expected to evacuate in the event of a fire or other emergency.  a) Throughout: The employer did not have a written emergency action plan (EAP) for the employees working in the Production Area.  The employer failed to communicate procedures to the employees in an event of a fire or other emergency evacuation.
Recent events (3)
  • — I $1300
  • — Z $2000
  • — Z (O) $0

1910.178 L01 I

Other-than-serious 1 instance 3 exposed
Issued
Jan 7, 2015
Abate by
Feb 3, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l):  a) Production Area; The employer had not evaluated his employees to ensure that each employee operating the Mitsubishi Model No. FGC25M (Serial No. AF82C-02197) was competent to operate the powered industrial truck while transporting, loading, and unloading steel sheets.