Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,194,531Inspections Most recent open 2026-08-11 Last loaded 2026-08-14

OSHA Inspection: COCA COLA REFRESHMENTS

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of COCA COLA REFRESHMENTS in 5126 GREENWOOD, CORPUS CHRISTI, TX 78417 (NAICS 424490). OSHA activity number 339978561.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Coca Cola Refreshments for free Get an email when a new federal OSHA severe-injury report for Coca Cola Refreshments is published. One employer, no account, unsubscribe in one click.
Site address
5126 GREENWOOD
City
CORPUS CHRISTI
State
TX
ZIP
78417
Mailing
5126 GREENWOOD, CORPUS CHRISTI, TX 78417
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
424490
Employees
150
Ownership type
Private (A)

6 citations on file for this inspection.

1910.303 B01 I

Other-than-serious 1 instance 5 exposed
Issued
Oct 29, 2014
Penalty
Initial $4,250 · Current $4,250
29 CFR 1910.303(b)(1)(i): Electrical equipment was not free from recognized hazards that were likely to cause death or serious physical harm to employees.  Safety of equipment shall be determined using the consideration of suitability for installation and use in conformity with the provisions of this subpart as evidenced by listing or labeling for that identified purpose:    On or about October 2, 2014, in the employee break room, two relocatable power taps (RPT) were interconnected or "daisy chained" to provide more outlets.  A TV, cable  box, Ice Beverage Dispenser, Ice Tea machine, microwave, toaster, and coffee machine were energized by these RPT's.
Recent events (2)
  • · I (O) $4250
  • · Z (S) $4250

1910.305 G01 IV

Other-than-serious 1 instance 5 exposed
Issued
Oct 29, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv): Unless specifically permitted otherwise in paragraph (g)(1)(ii) of this section, flexible cords and cables may not be used:    On or about October 2, 2014, in the employee break room, the cord to the surge protector was run through a hole in the countertop and plugged into an outlet.  The surge protector supplied power to appliances.
Recent events (2)
  • · I (O) $0
  • · Z (S) $0

1910.305 G02 III

Other-than-serious 2 instances 2 exposed
Issued
Oct 29, 2014
Penalty
Initial $4,250 · Current $4,250
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws:    On or about October 2, 2014, at this facility, at the rear loading docks, employees used the dock leveler on a daily basis to raise the ramps up and down for the oncoming trailers and strain relief was not provided on the leveler connections such as but not limited to:    (a) The bottom cable connected to the dock leveler between 3 & 4;    (b) The bottom cable connected to the dock leveler between 2 & 3 had been taped.      Change Standard to:  29 CFR 1910.305(b)(1)
Recent events (2)
  • · I (O) $4250
  • · Z (S) $4250

1910.22 B02

Other-than-serious 1 instance 2 exposed
Issued
Oct 29, 2014
Abate by
Nov 28, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.22(b)(2): Permanent aisles and passageways were not appropriately marked:  At this facility, throughout the warehouse, the passageways were not clearly labeled or not appropriately marked to guide the forklift operators from getting close to merchandise.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

1910.303 G01 II

Other-than-serious 1 instance 1 exposed
Issued
Oct 29, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(1)(ii): The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage:  At this facility, the electrical power box located by the POS area was blocked with debris.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

1910.305 B02

Other-than-serious 1 instance 2 exposed
Issued
Oct 29, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.305(b)(2): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy:  On October 2, 2014, at the southeast corner of the warehouse, by dock 7, the employee's radio was connected to the outlet and it did not have a face plate cover.  The employees were exposed to contact with live conductors.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

View Coca Cola Refreshments's full OSHA safety record →