Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: THE AUTO DEPOT LLC

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of THE AUTO DEPOT LLC in 1033 W DARTMOUTH AVE, ENGLEWOOD, CO 80110 (NAICS 811121). OSHA activity number 339982233.

Watch THE Auto Depot LLC — free Get an email when a new federal OSHA severe-injury report for THE Auto Depot LLC is published. One employer, no account, unsubscribe in one click.
Establishment
THE AUTO DEPOT LLC
Site address
1033 W DARTMOUTH AVE
City
ENGLEWOOD
State
CO
ZIP
80110
Mailing
1033 W DARTMOUTH AVE, ENGLEWOOD, CO 80110
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
811121
Employees
16
Ownership type
A

7 citations on file for this inspection.

1910.23 C01

Serious Gravity 5 1 instance 12 exposed
Issued
Abate by
Penalty
Initial $1700.00 · Current $850.00 Reduced
29 CFR 1910.23(c)(1): Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent):     a)  On or about October 1, 2014, and at times prior, employees were exposed to fall hazards of greater than 4 feet when they worked on the storage area above the offices in the main shop and on the shelving units in the shop because these levels were not equipped with standard railings.
Recent events (2)
  • — I (S) $850
  • — Z (S) $1700

1910.22 D01

Serious Gravity 1 1 instance 12 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.22(d)(1):  On every building or other structure, or part thereof, used for mercantile, business, industrial or storage purposes, the loads approved by the building official were not marked on plates of approved design and securely affixed to the building:        a)  On or about October 1, 2014, and at times prior, employees were exposed to struck-by or fall hazards while they worked under, around and on the storage shelves along the walls of the paint and detail shop.  The employer had not posted the load rating for the shelf structures.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1052 D02

Serious Gravity 1 1 instance 4 exposed
Issued
Penalty
Initial $867.00 · Current $434.00 Reduced
29 CFR 1910.1052(d)(2): The employer did not perform initial monitoring to determine each employee's exposure to methylene chloride:    a)  On or about October 1, 2014, and at times prior, employees were exposed to unknown concentrations of methylene chloride because the employer failed to conduct an initial exposure assessment for painting employees that used Klean Strip Naked Gun Spray Gun Paint Remover, which contained 30-60% methylene chloride, to remove paint from paint guns, tables and other surfaces.
Recent events (2)
  • — I (S) $433.5
  • — Z (S) $867

1910.1052 G03 I

Serious Gravity 1 1 instance 4 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.1052(g)(3)(i): The employer did not select and provide to employees, the appropriate atmosphere-supplying respirator specified in 29 CFR 1910.134(d)(3)(i)(A) and selected or used half masks:   a)  On or about October 1, 2014, and at times prior, employees were exposed to methylene chloride because the employer failed to provide them with a full-face atmosphere-supplying respirator while they used Klean Strip Naked Gun Spray Gun Paint Remover which contained 30-60% methylene chloride.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1200 E01

Serious Gravity 1 1 instance 12 exposed
Issued
Penalty
Initial $867.00 · Current $434.00 Reduced
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met:    a)  On or about October 1, 2014, and at times prior, the employer failed to fully develop and implement a hazard communication program in order to inform employees of the health hazards associated with the chemicals, such as methylene chloride, hydrofluoric acid and isocyanates, used in the body, paint and detail areas.
Recent events (2)
  • — I (S) $433.5
  • — Z (S) $867

1910.106 D04 IV

Other-than-serious 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.106(d)(4)(iv):  Every inside storage room shall be provided with either a gravity or mechanical exhaust ventilation system.  Such system shall be designed to provide for a complete change of air within the room at least six times per hour.  If a mechanical exhaust system is used, it shall be controlled by a switch outside the door.  The ventilating equipment and any lighting fixtures shall be operated by the same switch:    a)  On or about October 1, 2014, and at times prior, employees were exposed to fire and chemical exposure hazards because the employer did not ensure that the light fixture for the paint mixing/storage room and the ventilation were operated by the same switch.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.106 E09 III

Other-than-serious 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.106(e)(9)(iii): Combustible waste material and residues in a building or unit operating area were not kept to a minimum, stored in covered metal receptacles and disposed of daily:  a)  On or about October 1, 2014, and at times prior, employees were exposed to fire hazards because the employer did not ensure that the waste containers in the paint storage and mixing room were covered metal receptacles.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339982233.