Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,196,991Inspections Most recent open 2026-08-24 Last loaded 2026-08-27

OSHA Inspection: WILDLIFE CONSERVATION SOCIETY

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of WILDLIFE CONSERVATION SOCIETY in 502 SURF AVE & WEST 8TH STREET, BROOKLYN, NY 11224 (NAICS 712190). OSHA activity number 339991416.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Wildlife Conservation Society for free Get an email when a new federal OSHA severe-injury report for Wildlife Conservation Society is published. One employer, no account, unsubscribe in one click.
Site address
502 SURF AVE & WEST 8TH STREET
City
BROOKLYN
State
NY
ZIP
11224
Mailing
502 SURF AVE & WEST 8TH STREET, BROOKLYN, NY 11224
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Union (A)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
712190
Employees
80
Ownership type
Private (A)

13 citations on file for this inspection.

1910.22 A02

Deleted Serious Gravity 5 1 instance 6 exposed
Issued
Mar 18, 2015
Abate by
Mar 30, 2015
Penalty
Initial $2,800 · Current $0 Reduced
29 CFR 1910.22(a)(2): The floor of every workroom was not maintained in a clean and, so far as possible, a dry condition. Where wet processes are used, drainage was not maintained, and false floors, platforms, mats, or other dry standing places should be provided where practicable.  Site: 502 Surf Avenue & 8th Street Brooklyn, NY  On or about 10/8/14  a) Employees exposed to slip trip and falls due to water accumulation in the in the Glovers Reef pump room.
Recent events (3)
  • · F (S) $0
  • · C (S) $2800
  • · Z (S) $2800

1910.23 C01

Serious Gravity 10 1 instance 10 exposed
Issued
Mar 18, 2015
Abate by
Mar 30, 2015
Penalty
Initial $4,900 · Current $3,100 Reduced
29 CFR 1910.23(c)(1): Every open-sided floor or platform 4 feet or more above adjacent floor or ground level was not guarded by a standard railing (or the equivalent as specified in paragraph (e)(3) of this section) on all open sides except where there is entrance to a ramp, stairway, or fixed ladder. The railing shall be provided with a toeboard wherever, beneath the open sides.    Site: 502 Surf Avenue & West 8th Street Brooklyn, NY    On or about 10/8/14    a) No guardrails are provided in loading dock area.    b) Guardrails not fully installed on upper deck area by the Glovers Reef pump room. Employees were exposed to a fall approximately 15 feet to the ground floor.
Recent events (3)
  • · F (S) $3100
  • · C (S) $4900
  • · Z (S) $4900

1910.24 B

Other-than-serious 1 instance 6 exposed
Issued
Mar 18, 2015
Abate by
Mar 30, 2015
Penalty
Initial $2,100 · Current $1,300 Reduced
29 CFR 1910.24(b): Fixed stairs were not provided for access from one structure level to another where operations necessitated regular travel between levels, and for access to operating platforms at any equipment which requires attention routinely during operations:    Site: 502 Surf Avenue & West 8th Street Brooklyn, NY    On or about 10/8/14    a) Fixed stairs or other means of access were not provided to access the pump valve in the Glovers Reef pump room. Maintenance employees climb on pipes and other items to access the pump valve.
Recent events (3)
  • · F (O) $1300
  • · C (S) $2100
  • · Z (S) $2100

1910.36 D01

Other-than-serious 1 instance 6 exposed
Issued
Mar 18, 2015
Abate by
Mar 30, 2015
Penalty
Initial $4,900 · Current $1,000 Reduced
29 CFR 1910.36(d)(1): Employees were not be able to open an exit route door from the inside at all times without keys, tools, or special knowledge. A device such as a panic bar that locks only from the outside is permitted on exit discharge doors.        Site: 502 Surf Avenue & West 8th Street Brooklyn, NY    On or about 10/8/14    a) The emergency exit door in the Exhibit shop area was bolted from the inside.
Recent events (3)
  • · F (O) $1000
  • · C (S) $4900
  • · Z (S) $4900

1910.37 B04

Other-than-serious 1 instance 2 exposed
Issued
Mar 18, 2015
Abate by
Mar 30, 2015
Penalty
Initial $2,800 · Current $1,000 Reduced
29 CFR 1910.37(b)(4): Signs were not posted along the exit access indicating the direction of travel to the nearest exit and exit discharge when the direction of travel to the exit or exit discharge was not immediately apparent:    Site: 502 Surf Avenue & West 8th Street Brooklyn, NY    On or about 10/8/14    a) Exit signs indicating the direction of travel in the Operation Storage Warehouse were not provided. The route or direction of travel was not identified.
Recent events (3)
  • · F (O) $1000
  • · C (S) $2800
  • · Z (S) $2800

1910.37 B05

Other-than-serious 1 instance 2 exposed
Issued
Mar 18, 2015
Abate by
Mar 30, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.37(b)(5): Each doorway or passage along an exit access that could be mistaken for an exit was not marked "Not an Exit" or similar designation, or be identified by a sign indicating its actual use (e.g. closet):    Site: 502 Surf Avenue & West 8th Street Brooklyn, NY    On or about 10/8/14    a) Along the passageway in the Operation Storage Warehouse, the emergency door that leads to the exit was not labeled as such. There was no exit sign on it.
Recent events (3)
  • · F (O) $0
  • · C (S) $0
  • · Z (S) $0

1910.176 B

Other-than-serious 1 instance 8 exposed
Issued
Mar 18, 2015
Abate by
Mar 30, 2015
Penalty
Initial $2,800 · Current $0 Reduced
29 CFR 1910.176(b): Secure storage. Storage of material shall not create a hazard. Bags, containers, bundles, etc., stored in tiers shall be stacked, blocked, interlocked and limited in height so that they are stable and secure against sliding or collapse.    Site: 502 Surf Avenue & West 8th Street Brooklyn, NY    On or about 10/8/14    a) Air filters stored in the Gardening shop were stacked and at an height which was not stable and secure.      b) Lockers in the Temp trailers and in the Operation Storage warehouse were not anchored to the wall. The lockers were not stable and secured.
Recent events (3)
  • · F (O) $0
  • · C (S) $2800
  • · Z (S) $2800

1910.303 G02 I

Repeat 2 instances 9 exposed
Issued
Mar 18, 2015
Abate by
Mar 30, 2015
Penalty
Initial $2,800 · Current $1,000 Reduced
29 CFR 1910.303(g)(2)(i): Live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by approved cabinets of other forms of approved enclosures, or other means listed under this provision:      Site: 502 Surf Ave & West 8th Street Brooklyn, NY    On or about 10/8/14    a) Energized panel board was missing a cover.
Recent events (3)
  • · F (R) $1000
  • · C (S) $2800
  • · Z (S) $2800

1910.305 A02 X

Serious Gravity 1 1 instance 6 exposed
Issued
Mar 18, 2015
Abate by
Mar 30, 2015
Penalty
Initial $2,100 · Current $1,470 Reduced
29 CFR 1910.305(a)(2)(x): Flexible cords and cables were not protected from accidental damage, as might be caused, for example, by sharp corners, projections, and doorways or other pinch points.      Site: 502 Surf Avenue & West 8th Street Brooklyn, NY    On or about 10/8/14    a) Throughout the establishment flexible cord were not protected from accidental damage. Flexible cords were hanging on top of the doors and routed through door ways and around corners. Flexible cords were used to energize equipment.
Recent events (3)
  • · F (S) $1470
  • · C (S) $2100
  • · Z (S) $2100

1910.305 G01 IV B

Serious Gravity 1 1 instance 9 exposed
Issued
Mar 18, 2015
Abate by
Mar 30, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv)(B): Flexible cord were not protected from accidental damage when run through holes in walls, ceilings, or floors.  Site: 502 Surf Avenue and West 8th Street Brooklyn, NY  On or about 10/8/14  a) Flexible extension cords were run through wall holes without any abrasion protection.
Recent events (3)
  • · F (S) $0
  • · C (S) $0
  • · Z (S) $0

1910.305 B02 I

Deleted Serious Gravity 5 1 instance 9 exposed
Issued
Mar 18, 2015
Abate by
Mar 30, 2015
Penalty
Initial $2,800 · Current $0 Reduced
29 CFR 1910.305(b)(2)(i): All pull boxes, junction boxes, and fittings were not provided with covers identified for the purpose. If metal covers are used, they shall be grounded. In completed installations, each outlet box shall have a cover, faceplate, or fixture canopy. Covers of outlet boxes having holes through which flexible cord pendants pass shall be provided with bushings designed for the purpose or shall have smooth, well-rounded surfaces on which the cords may bear.  Site: 502 Surf Avenue & West 8th Street Brooklyn, NY  On or about 109/8/14  a) Junction boxes throughout the establishment were not provided with a cover.
Recent events (3)
  • · F (S) $0
  • · C (S) $2800
  • · Z (S) $2800

1910.305 G01 IV A

Deleted Serious Gravity 1 2 instances 9 exposed
Issued
Mar 18, 2015
Abate by
Mar 30, 2015
Penalty
Initial $2,100 · Current $0 Reduced
29 CFR 1910.305(g)(1)(iv)(A): 29 CFR 1910.305(g)(1)(iv)A: Unless specifically permitted otherwise in paragraph (g)(1)(ii) of this section, flexible cords and cables may not be used as a substitute for permanent building wiring.  Site: 502 Surf Ave & West 8th Street Brooklyn, NY  On or about 10/8/14  a) Extension cord in the Tool Shop/Work Shop and in the Operation Building were used as permanent wiring.
Recent events (3)
  • · F (S) $0
  • · C (S) $2100
  • · Z (S) $2100

1910.305 J02 IV

Other-than-serious 1 instance 6 exposed
Issued
Mar 18, 2015
Abate by
Mar 30, 2015
Penalty
Initial $4,200 · Current $2,700 Reduced
29 CFR 1910.305(j)(2)(iv): A receptacle installed in a wet or damp location was not suitable for the location.    Site: 502 Surf Avenue & West 8th Street Brooklyn, NY    On or about 10/8/14    a) The power cord for the pump in the Aqua Theater pump room was not protected from the wet conditions. The cord was not provided with rubber boot to protect from possible shock.
Recent events (3)
  • · F (O) $2700
  • · C (S) $4200
  • · Z (S) $4200

View Wildlife Conservation Society's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339991416.