Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: FANSTEEL INC.

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of FANSTEEL INC. in 513 E. 2ND STREET, EMPORIUM, PA 15834 (NAICS 332117). OSHA activity number 339991515.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Fansteel INC. — free Get an email when a new federal OSHA severe-injury report for Fansteel INC. is published. One employer, no account, unsubscribe in one click.
Establishment
FANSTEEL INC.
Site address
513 E. 2ND STREET
City
EMPORIUM
State
PA
ZIP
15834
Mailing
513 E. 2ND STREET, EMPORIUM, PA 15834
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332117
Employees
72
Ownership type
A

6 citations on file for this inspection.

1910.95 G08 II B

Serious Gravity 5 1 instance 1 exposed
Issued
Nov 14, 2014
Abate by
Jan 31, 2015
Penalty
Initial $4,200 · Current $1,800 Reduced
29 CFR 1910.95(g)(8)(ii)(B): Unless a physician determines that the standard threshold shift is not work-related or aggravated by occupational noise exposure, the employer did not ensure, when a standard threshold shift occurs, that for employees already using hearing protectors, employees be refitted and retrained in the use of hearing protectors and provided with hearing protectors offering greater attenuation if necessary:          a.)    Fansteel, Inc. dba American Sintered Technologies, 513 E. 2nd Street, Emporium, PA 15834, on or about October 8th, 2014, and times prior thereto:  The employer did not institute a continuing effective hearing conservation program when employee noise exposures exceeded an 8-hour time-weighted average sound level of 85 dBA.  An employee, (Sintering Technician) was exposed to noise at a level of 81.10% of the allowable limit during a 440 minute sampling period on October 8, 2014.  This exposure is equivalent to a sound level of 88.9 dBA for the dose and time of the employee exposure.  The employer failed to conduct refitting and retraining on hearing protectors for an employee who experienced a Standard Threshold Shift.  Additionally, the employer did not determine if the employee required hearing protection with greater attenuation.
Recent events (2)
  • — I (S) $1800
  • — Z (S) $4200

1910.95 K02

Serious Gravity 5 1 instance 2 exposed
Issued
Nov 14, 2014
Abate by
Jan 31, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.95(k)(2): The training program was not repeated annually for each employee included in the hearing conservation program:           a.)    Fansteel, Inc. dba American Sintered Technologies, 513 E. 2nd Street, Emporium, PA 15834, on or about October 8th, 2014, and times prior thereto:  The employer did not annually train each employee on the proper use and fitting of hearing protection who were exposed to the noise that exceeded an 8-hour time-weighted average sound level of 85 dBA.  An employee, (Sintering Technician) was exposed to noise at a level of 81.10 % of the allowable limit during a 440 minute sampling period on October 8, 2014.  This exposure is equivalent to a sound level of 88.9 dBA for the dose and time of the employee exposure.  Employees who were included in the Employer's Hearing Conservation Program were not trained on the proper use, and fitting of hearing protection as evidence by the improper use of hearing protection onsite.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.95 I05

Serious Gravity 5 1 instance 2 exposed
Issued
Nov 14, 2014
Abate by
Jan 31, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.95(i)(5): The employer did not ensure proper initial fitting and supervise the correct use of all hearing protectors:           a.)    Fansteel, Inc. dba American Sintered Technologies, 513 E. 2nd Street, Emporium, PA 15834, on or about October 8th, 2014:  The employer did not institute a continuing effective hearing conservation program when employee noise exposures exceeded an 8-hour time-weighted average sound level of 85 dBA.  An employee, (Sintering Technician) was exposed to noise at a level of 81.10% of the allowable limit during a 440 minute sampling period on October 8, 2014.  The Employer did not ensure that employees were wearing their Moldex Brand 6604 ear plugs properly.  An employee's ear plug was not inserted/used correctly as it was observed not fully inserted into the employee's ear canal.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.178 Q07

Serious Gravity 5 1 instance 3 exposed
Issued
Nov 14, 2014
Abate by
Jan 31, 2015
Penalty
Initial $2,800 · Current $2,000 Reduced
29 CFR 1910.178(q)(7): Powered industrial truck(s) which were used on a round-the-clock basis were not examined for defects after each shift:       a.)    Fansteel, Inc. dba American Sintered Technologies, 513 E. 2nd Street, Emporium, PA 15834, on or about October 8th, 2014, and times prior thereto:  Employees operated a Komatsu FT2 model # FG35ST-7 (Serial # 100050A) industrial truck daily and/or over multiple work shifts.  The Komatsu FT2 #FG35ST-7 industrial truck was not being examined daily or after each work shift.
Recent events (2)
  • — I (S) $2000
  • — Z (S) $2800

1910.178 Q01

Deleted Serious Gravity 5 1 instance 3 exposed
Issued
Nov 14, 2014
Abate by
Dec 11, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.178(q)(1): Any power-operated industrial truck not in safe operating condition was not taken out of service, and/or repairs were not made by authorized personnel:    a.) Fansteel, Inc. dba American Sintered Technologies, 513 E. 2nd Street, Emporium, PA 15834, on or about October 8th, 2014, and times prior thereto:  Employees utilized a liquid propane powered Komatsu FT2 model # FG35ST-7 (Serial # 100050A) industrial truck throughout the production areas of the facility.  The Komatsu FT2 #FG35ST-7 industrial truck was exhausting Carbon Monoxide at levels up to, and including, 564 parts per million and needed mechanical repair.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 C02 I

Other-than-serious 1 instance 3 exposed
Issued
Nov 14, 2014
Abate by
Dec 31, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.134(c)(2)(i): Respirator users were not provided with the information contained in Appendix D to 29 CFR 1910.134 when the employer determined that any voluntary respirator use was permissible:     a.) Fansteel, Inc. dba American Sintered Technologies, 513 E. 2nd Street, Emporium, PA 15834, on or about October 8th, 2014, and times prior thereto:  Employees used 3M brand and Champion brand dust masks on a voluntary basis during certain pouring operations in the powder room.  Employees that used the dust masks were not provided with the information in Appendix D to this section.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Fansteel INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339991515.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.