DUBLIN, GA —
OSHA Inspection: DINEX EMISSION, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of DINEX EMISSION, INC. in 2020 WALDREP INDUSTRIAL BLVD., DUBLIN, GA 31021 (NAICS 336322). OSHA activity number 339995730.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- DINEX EMISSION, INC.
- Site address
- 2020 WALDREP INDUSTRIAL BLVD.
- City
- DUBLIN
- State
- GA
- ZIP
- 31021
- Mailing
- 2020 WALDREP INDUSTRIAL BLVD., DUBLIN, GA 31021
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 336322
- Employees
- 48
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.178 P01
- Issued
- Dec 3, 2014
- Abate by
- Jan 15, 2015
- Penalty
- Initial $2,975 · Current $1,785 Reduced
General-duty citation text
29 CFR 1910.178(p)(1): Powered industrial truck(s) found to be in need of repair, defective, or in any way unsafe had not been taken out of service until restored to safe operating condition(s): a) Throughout the facility - on or about October 08, 2014 and at times prior to, employees were exposed to a hazard of being struck by powered industrial trucks (PITs) due to employees operating a Nissan forklift AL 400 that did not have functioning headlights.
Recent events (2)
- — I (S) $1785
- — Z (S) $2975
1910.1200 G01
- Issued
- Dec 3, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(g)(1): The employer did not have a material safety data sheet for each hazardous chemical in use: a) At the facility, on or about October 08, 2014, the employer did not have safety data sheets (SDS) for hazardous chemicals such as, acrylic enamel paint, primer, propane, welding rods, stainless steel, aluminized steel and acetone used by employees at the facility, exposing employees to eye irritation and irritation to the respiratory system.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Dinex Emission, INC.