OSHA Inspection: A & M CONSTRUCTION & ROOFING, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of A & M CONSTRUCTION & ROOFING, INC. in 2331 PARKSIDE AVE., CHICAGO, IL 60639 (NAICS 238160). OSHA activity number 340001320.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch A & M Construction & Roofing, INC. — free Get an email when a new federal OSHA severe-injury report for A & M Construction & Roofing, INC. is published. One employer, no account, unsubscribe in one click.
Site address
2331 PARKSIDE AVE.
City
CHICAGO
State
IL
ZIP
60639
Mailing
2518 GOLFVIEW ST., JOLIET, IL 60435
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
6
Ownership type
A

5 citations on file for this inspection.

1903.19 C01

Other-than-serious 1 instance 1 exposed
Issued
Mar 2, 2015
Abate by
Apr 2, 2015
Penalty
Initial $400 · Current $400
29 CFR 1903.19(c)(1):  The employer did not certify to OSHA, within 10 calendar days after the abatement date, that the cited violation had been abated:     A & M Construction & Roofing, Inc., failed to certify to OSHA within 10 calendar days after the abatement date that each of the following cited violations had been corrected:     Citation Number                              Item Number                                    Abatement Date  01                                                           01                                                           12/11/2014  01                                                           02                                                           12/11/2014  01                                                           03                                                           12/11/2014  01                                                           04                                                           12/11/2014    In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (1)
  • — Z (O) $400

1926.501 B13

Serious Gravity 10 1 instance 6 exposed
Issued
Dec 1, 2014
Abate by
Dec 11, 2014
Penalty
Initial $2,800 · Current $2,800
29 CFR 1926.501(b)(13):  Each employee engaged in residential construction activities 6 feet or more above lower levels was not protected by guardrail systems, safety net systems, or personal fall arrest systems, nor did the employer demonstrate that it is infeasible or creates a greater hazard to use these systems and develop and implement a fall protection plan which meets the requirements of paragraph (k) of section 1926.502:    a)  Employees performing roofing work were exposed to fall hazards of approximately 13 feet.    In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (1)
  • — Z (S) $2800

1926.1053 B01

Serious Gravity 5 2 instances 6 exposed
Issued
Dec 1, 2014
Abate by
Dec 11, 2014
Penalty
Initial $2,000 · Current $2,000
29 CFR 1926.1053(b)(1):  Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access:  a)  Employees were using an extension ladder which did not extend 3 feet above the upper landing being accessed.     In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (1)
  • — Z (S) $2000

1926.1053 B04

Serious Gravity 5 1 instance 6 exposed
Issued
Dec 1, 2014
Abate by
Dec 11, 2014
Penalty
Initial $2,000 · Current $2,000
29 CFR 1926.1053(b)(4):  Ladder(s) were used for purposes other than the purpose for which they were designed:  a)  Employees were exposed to fall hazards while using the top half of an extension ladder as a stand alone ladder.  In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (1)
  • — Z (S) $2000

1926.1053 B22

Serious Gravity 5 2 instances 6 exposed
Issued
Dec 1, 2014
Abate by
Dec 11, 2014
Penalty
Initial $2,000 · Current $2,000
29 CFR 1926.1053(b)(22): Employees using ladders were carrying objects or loads that could cause the employee to lose balance and fall:  a) Employees were exposed to fall hazards while carrying bundles of material up extension ladders.  In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (1)
  • — Z (S) $2000

View A & M Construction & Roofing, INC.'s full OSHA safety record →