FENTON, MO —
OSHA Inspection: KOLLER-CRAFT PLASTIC PRODUCTS
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of KOLLER-CRAFT PLASTIC PRODUCTS in 1400 OLD HIGHWAY 141, FENTON, MO 63026 (NAICS 326199). OSHA activity number 340001924.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- KOLLER-CRAFT PLASTIC PRODUCTS
- Site address
- 1400 OLD HIGHWAY 141
- City
- FENTON
- State
- MO
- ZIP
- 63026
- Mailing
- 1400 OLD HIGHWAY 141, FENTON, MO 63026
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 326199
- Employees
- 100
- Ownership type
- A
Citations
7 citations on file for this inspection.
1910.101 B
- Issued
- Oct 17, 2014
- Abate by
- Dec 5, 2014
- Penalty
- Initial $5,000 · Current $0 Reduced
General-duty citation text
29 CFR 1910.101(b): Section 3.4.4., Compressed Gas Association Pamphlet P-1-1965, as adopted by 29 CFR 1910.101(b): Compressed gas cylinder(s) in storage were not properly supported to prevent them from being knocked over: a/ Inside of the Maintenance Department, one compressed gas cylinder, partially filled with oxygen, was not secured to prevent displacement.
Recent events (3)
- — F (S) $0
- — C (S) $5000
- — Z (S) $5000
1910.136 A
- Issued
- Oct 17, 2014
- Abate by
- Dec 5, 2014
- Penalty
- Initial $5,000 · Current $0 Reduced
General-duty citation text
29 CFR 1910.136(a): The employer did not ensure that each affected employee used protective footwear when working in areas where there was a danger of foot injuries due to falling or rolling objects, or objects piercing the sole, and where such employee's feet were exposed to electrical hazards: a/ Inside of the Tool & Die Department, employee(s) were operating a ten ton overhead bridge crane, unknown make, model, or serial number via a pendant control while wearing sneakers. The weight of the suspended die 1413-23 was estimated to be 1,000 pounds.
Recent events (3)
- — F (S) $0
- — C (S) $5000
- — Z (S) $5000
1910.147 C04 II
- Issued
- Oct 17, 2014
- Abate by
- Dec 5, 2014
- Penalty
- Initial $5,000 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(ii): The energy control procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, including, but not limited to items A-D of this section: Inside of Bay 1, Bay 2, and Bay 3, the specific energy control procedures for the following presses failed to identify thermal energy as a source or the techniques necessary to isolate this hazard: a/ Toshiba ISGT950WV21-81B/455310. b/ VanDorn Demag 1100CC6800C-0223. c/ Husky H10000 RS95/95SN:3575795. d/ Toshiba ISF1450DV10-110/812007. e/ Toshiba ISF1450DV10-110/812007. f/ VanDorn Demag 1100CC6800-0156. g/ UBE UZ1500 #19465. h/ Husky QW2000 RS 155/135. i/ UBE ST2000US-400 #21472. j/ Mitsibishi 2200MM111-240 #3M2024032. k/ HPM Next Wave HM2750 #98058. l/ Toshiba ISF310S11-19A #805E76. m/ Toshiba ISF310SH-19A #815E84. n/ Toshiba ISGS310V10-19AT/834906. o/ NISSEI FNX460111-160A/S24612018K1. p/ Toshiba ISF500S11-34B/815508. q/ Toshiba ISGT950WV21-81AT/452501. r/ NISSEI FS80S12ASE #S08L149. s/ NISSEI FS80S12ASE #S08J097. t/ NISSEI FS120S18ASE #S12J257. u/ Toshiba EC180V21-4B/902012. v/ Toshiba ISG190NV10-5B/711112. w/ NISSEI FS210S50ASE #S21J043. x/ VanDorn Demag 300HT1920-3349. y/ Toshiba ISGS390V10-27B/096309.
Recent events (3)
- — F (S) $0
- — C (S) $5000
- — Z (S) $5000
1910.147 C06 II
- Issued
- Oct 17, 2014
- Abate by
- Dec 8, 2015
- Penalty
- Initial $5,000 · Current $2,000 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(ii): The employer shall certify that the periodic inspections have been performed. The certification shall identify the machine or equipment on which the energy control procedure was being utilized, the date of the inspection, the employees included in the inspection, and the person performing the inspection. (a) Certification of periodic inspection were not documented for the following machines/presses in Bays 1, 2 and 3: a/ Toshiba ISGT950WV21-81B/455310. b/ VanDorn Demag 1100CC6800C-0223. c/ Husky H10000 RS95/95SN:3575795. d/ Toshiba ISF1450DV10-110/812007. e/ Toshiba ISF1450DV10-110/812007. f/ VanDorn Demag 1100CC6800-0156. g/ UBE UZ1500 #19465. h/ Husky QW2000 RS 155/135. i/ UBE ST2000US-400 #21472. j/ Mitsibishi 2200MM111-240 #3M2024032. k/ HPM Next Wave HM2750 #98058. l/ Toshiba ISF310S11-19A #805E76. m/ Toshiba ISF310SH-19A #815E84. n/ Toshiba ISGS310V10-19AT/834906. o/ NISSEI FNX460111-160A/S24612018K1. p/ Toshiba ISF500S11-34B/815508. q/ Toshiba ISGT950WV21-81AT/452501. r/ NISSEI FS80S12ASE #S08L149. s/ NISSEI FS80S12ASE #S08J097. t/ NISSEI FS120S18ASE #S12J257. u/ Toshiba EC180V21-4B/902012. v/ Toshiba ISG190NV10-5B/711112. w/ NISSEI FS210S50ASE #S21J043. x/ VanDorn Demag 300HT1920-3349. y/ Toshiba ISGS390V10-27B/096309.
Recent events (3)
- — F (O) $2000
- — C (S) $5000
- — Z (S) $5000
1910.212 A01
- Issued
- Oct 17, 2014
- Abate by
- Dec 8, 2015
- Penalty
- Initial $5,000 · Current $4,000 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding were not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: Inside of the Maintenance Area, the spindle, chuck, and unused portion of the bit belonging to the following machine was unguarded: a/ TWS Drill Press, m/n F2212S, s/n 001289. Inside of the Tool & Die Department, the following machines were unguarded: a/ Fosdick Radial Arm Drill, unknown m/n, unknown s/n. b/ Cincinnati Milling Machine, unknown m/n, unknown s/n. c/ Bridgeport Milling Machine, Series I, s/n 99583. d/ Victor Lathe, m/n VICTOR-1340GHE, s/n 086-03-089. e/ ENCO Milling Machine, unknown m/n, s/n 501745. f/ Baldor Vertical Sander, unknown m/n, s/n 35333-5561.
Recent events (3)
- — F (S) $4000
- — C (S) $5000
- — Z (S) $5000
1910.212 B
- Issued
- Oct 17, 2014
- Abate by
- Dec 8, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.212(b): Machines designed for a fixed location were not securely anchored to prevent walking or moving: Inside of the Maintenance Department, the following machine was not anchored: a/ TWS Drill Press, m/n F2212S, s/n 001209. Inside of the Tool & Die Department, the following machine was not anchored: a/ Dayton Bench Grinder, m/n 4Z360, s/n 642.
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
1910.219 E01 I
- Issued
- Oct 17, 2014
- Abate by
- Dec 8, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.219(e)(1)(i): Horizontal belts which had both runs seven feet or less from the floor level were not fully enclosed by guards conforming to the requirements specified in 29 CFR 1910.219: a/ Inside of the Tool & Die Department, the horizontal belts located with the motor housing belonging to ENCO Milling Machine, unknown m/n, s/n 501745, were unguarded. These belts were approximately six feet above the floor.
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
More inspections at Koller-Craft Plastic Products
View Koller-Craft Plastic Products's full OSHA safety record →
More inspections in this industry (NAICS 326199)
More inspections in MO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340001924.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.