DELRAN, NJ —
OSHA Inspection: LAUDA-BRINKMANN, LP
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of LAUDA-BRINKMANN, LP in 1819 UNDERWOOD BOULEVARD SUITE # 2, DELRAN, NJ 08075 (NAICS 423490). OSHA activity number 340012699.
Where did this inspection happen?
- Establishment
- LAUDA-BRINKMANN, LP
- Site address
- 1819 UNDERWOOD BOULEVARD SUITE # 2
- City
- DELRAN
- State
- NJ
- ZIP
- 08075
- Mailing
- 1819 UNDERWOOD BOULEVARD SUITE # 2, DELRAN, NJ 08075
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 423490
- Employees
- 15
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.101 B
- Issued
- Abate by
- Penalty
- Initial $1200.00 · Current $900.00 Reduced
General-duty citation text
29 CFR 1910.101(b): 29 CFR 1910.101(b): Section 3.4.4, Compressed Gas Association Pamphlet P11965, as adopted by 29 CFR 1910.101(b): Compressed gas cylinder(s) not in use were not properly supported to prevent them from being knocked over: a) Lauda Brinkmann - Maintenance/service area: Employees are exposed to struck by hazards when a suitable cylinder truck, chain, or other steadying device was not used to keep compressed gas cylinder(s) from being knocked over while been use or stored, observed on or about 10/10/2014.
Recent events (2)
- — I (S) $900
- — Z (S) $1200
1910.134 E01
- Issued
- Abate by
- Penalty
- Initial $1200.00 · Current $900.00 Reduced
General-duty citation text
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employees ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: a) Lauda Brinkmann - Service/maintenance shop: The employer did not provide medical evaluation to employees using 3M half mask respirators with P100 Multi Gas/Vapor Cartridge/Filter 60926 when using chemicals for brazing operations as well as the 134a Refrigerant. Condition noted on or about 10/10/2014.
Recent events (2)
- — I (S) $900
- — Z (S) $1200
1910.178 L04 III
- Issued
- Abate by
- Penalty
- Initial $1200.00 · Current $900.00 Reduced
General-duty citation text
29 CFR 1910.178(l)(4)(iii): An evaluation of each powered industrial truck operator's performance was not being conducted at least once every three years: a) Lauda Brinkmann - Service/maintenance shop: The Company forklift operators were not evaluated every three years in their ability to operate the powered industrial truck safely. Occurred on or about 10/10/2014.
Recent events (2)
- — I (S) $900
- — Z (S) $1200
1910.134 C01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.134(c)(1): The employer did not establish and implement a written respiratory protection program with worksite-specific procedures in any workplace where respirators are necessary to protect the health of the employee or whenever respirators are required by the employer: a) Lauda Brinkmann - Service/maintenance shop: The employer did not establish a written respiratory protection program for employees using 3M half mask respirators with P100 Multi Gas/Vapor Cartridge/Filter 60926 when using chemicals including but not limited to the 134a Refrigerant. Condition noted on or about 10/10/2014.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 423490)
SWEDESBORO, NJ—2026-05-06 00:00:00
THOMAS SCIENTIFIC, LLC
TUCSON, AZ—2026-01-06 00:00:00
CPX2026XBM831X0007 - MSE SUPPLIES LLC
BLANDON, PA—2025-12-19 00:00:00
EXCELSIOR BLOWER SYSTEMS, INC.
LIVERMORE, CA—2025-10-22 00:00:00
GOVERNMENT SCIENTIFIC SOURCE, INC.
SAN JUAN, PR—2025-10-15 00:00:00
ARTIFEX SOLUTIONS, LLC
More inspections in NJ
PERTH AMBOY, NJ—2026-07-16 00:00:00
ENGLERT INC.
RIDGEFIELD, NJ—2026-07-16 00:00:00
COLORITE PLASTICS COMPANY
BERLIN, NJ—2026-07-16 00:00:00
URUS CONSTRUCTION CORPORATION
GLASSBORO, NJ—2026-07-15 00:00:00
GLASSBORO WATER & SEWER DEPARTMENT
FLANDERS, NJ—2026-07-15 00:00:00
TRI-STATE QUIKRETE
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340012699.