MIAMISBURG, OH —
OSHA Inspection: METAL SHREDDERS, INC.
Unprogrammed Related inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Related safety inspection of METAL SHREDDERS, INC. in 5101 FARMERSVILLE WEST CARROLLTON RD, MIAMISBURG, OH 45342 (NAICS 423930). OSHA activity number 340014703.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- METAL SHREDDERS, INC.
- Site address
- 5101 FARMERSVILLE WEST CARROLLTON RD
- City
- MIAMISBURG
- State
- OH
- ZIP
- 45342
- Mailing
- 5101 FARMERSVILLE WEST CARROLLTON ROAD, MIAMISBURG, OH 45342
What kind of inspection was it?
- Inspection type
- Unprogrammed Related (G)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 423930
- Employees
- 30
- Ownership type
- A
Citations
10 citations on file for this inspection.
5(a)(1)
- Issued
- Apr 14, 2015
- Abate by
- Jun 1, 2015
- Penalty
- Initial $7,000 · Current $7,000
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees exposed to electrocution from using a Mark 1 Voltage Detector with fiberglass reinforced plastic rods that had not been tested to confirm that the fiberglass reinforced plastic rods were safe for use in live line tools: On or about October 16, 2014, at the Metal Shredders, Inc., DP&L/Metal Shredders industrial substation, a site-supervisor was exposed to an electrocution hazard by using a Mark I Voltage Detector equipped with fiberglass reinforced plastic rods that were approximately 15 years old and that had not been tested to confirm that the fiberglass reinforced plastic rods were safe for use in live line tools. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence, or written records.
Recent events (3)
- — F (S) $7000
- — C (S) $7000
- — Z (S) $7000
5(a)(1)
- Issued
- Apr 14, 2015
- Abate by
- Jun 1, 2015
- Penalty
- Initial $7,000 · Current $0 Reduced
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees exposed to electrocution from a 3-phase 4.16kv and a 480 Volt electrical line that was not grounded. On or before October 16, 2014 at the Metal Shredders, Inc. DP&L/Metal Shredders, Inc. 4.16kv dual-access substation, a site supervisor was exposed to an electrocution hazard where after testing the three phase 4.16kv electrical lines inside Cabinet #3 and at the 480 Volt AC industrial substation, did not install temporary grounds to remove the potential of electrical voltage differences in the substation. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence, or written records.
Recent events (3)
- — F (S) $0
- — C (S) $7000
- — Z (S) $7000
1910.332 B03 I
- Issued
- Apr 14, 2015
- Abate by
- Jun 1, 2015
- Penalty
- Initial $7,000 · Current $5,000 Reduced
General-duty citation text
29 CFR 1910.332(b)(3)(i): The skills and techniques necessary to distinguish exposed live parts from other parts of electric equipment. The employer did not provide additional training on being a qualified person to a site-supervisor on the electrical safety-related work practices before entering into the 4.16kv DP&L/Metal Shredders, Inc. dual-access substation on October 16, 2014 to de-energize and test the electrical disconnect switchgear in Cabinet #3. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence, or written records.
Recent events (3)
- — F (S) $5000
- — C (S) $7000
- — Z (S) $7000
1910.332 B03 II
- Issued
- Apr 14, 2015
- Abate by
- Jun 1, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.332(b)(3)(ii): The skills and techniques necessary to determine the nominal voltage of exposed live parts, and The employer did not provide training to a site supervisor on the skills and techniques necessary to determine the nominal voltage of exposed live parts as a qualified person before he entered a DP&L/Metal Shredders, Inc. 4.16Kv dual-access substation on October 16 2014, utilizing a Mark 1 Voltage Detector, 0-15kv range, to determine if the 3 phase electrical switchgear was energized. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence, or written records.
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
1910.333 B02 I
- Issued
- Apr 14, 2015
- Abate by
- Jun 1, 2015
- Penalty
- Initial $5,000 · Current $5,000
General-duty citation text
29 CFR 1910.333(b)(2)(i): "Procedures." The employer shall maintain a written copy of the procedures outlined in paragraph (b)(2) and shall make it available for inspection by employees and by the Assistant Secretary of Labor and his or her authorized representatives. Note: The written procedures may be in the form of a copy of paragraph (b) of this section. The Company had not maintained a copy of the procedures outlined in paragraph (b)(2) or incorporated the requirements of (b)(2) (iii)(D) and (b)(2)(iv)(B) in 29CFR1910.147. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence, or written records.
Recent events (3)
- — F (S) $5000
- — C (S) $5000
- — Z (S) $5000
1910.333 B02 II A
- Issued
- Apr 14, 2015
- Abate by
- Jun 1, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.333(b)(2)(ii)(A): Safe procedures for deenergizing circuits and equipment shall be determined before circuits or equipment are deenergized. The employer had not developed a safe procedure for deenergizing circuits including the middle switch blade on the electrical switchgear within a DP&L/Metal Shredders, Inc. 4.16kv dual-access substation that was stuck in the closed position before entering the substation on October 16, 2014 that included procedures such as but not limited to; the use of PPE for the arc flash hazard and how to test the electrical lines with a voltage detector. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence, or written records.
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
1910.333 B02 III A
- Issued
- Apr 14, 2015
- Abate by
- Jun 1, 2015
- Penalty
- Initial $5,000 · Current $4,000 Reduced
General-duty citation text
29 CFR 1910.333(b)(2)(iii)(A): A lock and a tag shall be placed on each disconnecting means used to de-energize circuits and equipment on which work is to be performed, except as provided in paragraphs (b)(2)(iii)(C) and (b)(2)(iii)(E) of this section. The lock shall be attached so as to prevent persons from operating the disconnecting means unless they resort to undue force or the use of tools. On or about October 16, 2014, in the DP&L/Metal Shredders, Inc. dual-access substation, the site supervisor who threw the disconnecting means on the 4.16Kv electric switchgear inside Cabinet #3 did not place a lock and tag on the disconnecting means. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence, or written records.
Recent events (3)
- — F (S) $4000
- — C (S) $5000
- — Z (S) $5000
1910.334 C01
- Issued
- Apr 14, 2015
- Abate by
- Jun 1, 2015
- Penalty
- Initial $7,000 · Current $7,000
General-duty citation text
29 CFR 1910.334(c)(1): Use. Only qualified persons may perform testing work on electric circuits or equipment. On or about October 16, 2014, inside the DP&L/Metal Shredders, Inc. dual-access substation, a site supervisor was using a Mark 1 Voltage Detector on a three phase 4.16KV electrical switchgear inside Cabinet #3, and was not qualified to perform the testing due to the failure identify any voltage due to the middle knife blade being stuck in the closed position on the electrical switchgear and still energized, 2400 volts to ground. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence, or written records.
Recent events (3)
- — F (S) $7000
- — C (S) $7000
- — Z (S) $7000
1910.335 A01 I
- Issued
- Apr 14, 2015
- Abate by
- Jun 1, 2015
- Penalty
- Initial $7,000 · Current $7,000
General-duty citation text
29 CFR 1910.335(a)(1)(i): Employees working in areas where there are potential electrical hazards shall be provided with, and shall use, electrical protective equipment that is appropriate for the specific parts of the body to be protected and for the work to be performed. Note: Personal protective equipment requirements are contained in subpart I of this part. On or about October 16, 2014, inside Cabinet #3 of the DP&L/Metal Shredders, Inc. dual-access substation, a site supervisor who was using a Mark 1 Voltage Detector to test for the absence of voltage on the 4.16Kv electrical circuits was exposed to burns and electric shock, electrocution hazards from the inadequate use of body, and hand protection based on the risk while Cabinet #3 was open and he was testing the three phase electrical lines for voltage. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence, or written records.
Recent events (3)
- — F (S) $7000
- — C (S) $7000
- — Z (S) $7000
1910.333 B02 IV B
- Issued
- Apr 14, 2015
- Abate by
- Jun 1, 2015
- Penalty
- Initial $70,000 · Current $28,250 Reduced
General-duty citation text
29 CFR 1910.333(b)(2)(iv)(B): A qualified person shall use test equipment to test the circuit elements and electrical parts of equipment to which employees will be exposed and shall verify that the circuit elements and equipment parts are deenergized. The test shall also determine if any energized condition exists as a result of inadvertently induced voltage or unrelated voltage backfeed even though specific parts of the circuit have been deenergized and presumed to be safe. If the circuit to be tested is over 600 volts, nominal, the test equipment shall be checked for proper operation immediately after this test. On or about October 16, 2014, an unqualified site supervisor tested the 3 phase electrical switchgear located in Cabinet #3 of the 4.16kv DP&L/Metal Shredders, Inc. dual-access industrial substation. The site supervisor utilized a Mark 1 Voltage Detector to test the 3 phase 4.16 kv electrical lines which showed one of the three phase legs still energized around 2400 volts. The unqualified site supervisor did not check the Mark 1 Voltage Detector for proper operation before and immediately after the test. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence, or written records.
Recent events (3)
- — F (R) $28250
- — C (W) $70000
- — Z (W) $70000
More inspections at Metal Shredders, INC.
View Metal Shredders, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 423930)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340014703.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.