Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: CONECSUS, LLC

Follow-up inspection · Health discipline

On , OSHA opened a follow-up health inspection of CONECSUS, LLC in 106 TEJAS DRIVE, TERRELL, TX 75160 (NAICS 331492). OSHA activity number 340028927.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Conecsus, LLC — free Get an email when a new federal OSHA severe-injury report for Conecsus, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
CONECSUS, LLC
Site address
106 TEJAS DRIVE
City
TERRELL
State
TX
ZIP
75160
Mailing
106 TEJAS DRIVE, TERRELL, TX 75160
Inspection type
Follow-up (F)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
331492
Employees
44
Ownership type
A

2 citations on file for this inspection.

1910.1018 G01 I

Serious Gravity 5 4 instances 15 exposed
Issued
Mar 3, 2015
Abate by
Aug 17, 2015
Penalty
Initial $7,700 · Current $3,000 Reduced
29 CFR 1910.1018(g)(1)(i): Engineering and work practice controls were not instituted to reduce inorganic arsenic exposure to or below permissible exposure limit:    This violation occurred on or about December 18, 2014, when the employer had not implemented engineering and work practice controls to reduce employee exposure to arsenic to or below the permissible exposure limit:      a) A rotary furnace operator was exposed to arsenic at an 8-hour time-weighted average concentration of 38 µg/m3, approximately 3.8 times the permissible exposure limit of 10 µg/m3.  Sampling was performed for 462 minutes during one shift.  Zero exposure was assumed for the unsampled period of 18 minutes.    b) A wastewater treatment equipment operator was exposed to arsenic at an 8-hour time-weighted average concentration of 26 µg/m3, approximately 2.6 times the permissible exposure limit of 10 µg/m3.  Sampling was performed for 473 minutes during one shift.  Zero exposure was assumed for the unsampled period of 7 minutes.    c) A kettle operator was exposed to arsenic at an 8-hour time-weighted average concentration of 100 µg/m3, approximately 10 times the permissible exposure limit of 10 µg/m3.  Sampling was performed for 471 minutes during one shift.  Zero exposure was assumed for the unsampled period of 9 minutes.    d) A truck loader was exposed to arsenic at an 8-hour time-weighted average concentration of 29 µg/m3, approximately 2.9 times the permissible exposure limit of 10 µg/m3.  Sampling was performed for 448 minutes during one shift.  Zero exposure was assumed for the unsampled period of 32 minutes.    Conecsus, LLC was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.1018(g)(1)(i), which was contained in OSHA inspection number 575358, citation number 1, item number 3a and was affirmed as final order on February 5, 2013, with respect to a workplace located at 106 Tejas Drive, Terrell, Texas 75160.
Recent events (2)
  • — I (S) $3000
  • — Z (R) $7700

1910.1025 E01 I

Serious Gravity 5 6 instances 27 exposed
Issued
Mar 3, 2015
Abate by
Aug 17, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.1025(e)(1)(i): For any employees exposed to lead above the permissible exposure limit for more than 30 days per year the employer did not implement engineering and work practice controls (including administrative controls) to reduce and maintain employee exposure to lead:     This violation occurred on or about December 18, 2014, when the employer had not implemented engineering and work practice controls to reduce employee exposure to lead to or below the permissible exposure limit:    a) A maintenance worker was exposed to lead at an 8-hour time-weighted average concentration of 210 µg/m3, approximately 4.2 times the permissible exposure limit of 50 µg/m3.   Sampling was performed for 464 minutes during one shift.  Zero exposure was assumed for the unsampled period of 16 minutes.    b) A vacuum distillation unit operator was exposed to lead at an 8-hour time-weighted average concentration of 490 µg/m3, approximately 9.8 times the permissible exposure limit of 50 µg/m3.   Sampling was performed for 480 minutes during one shift.      c) A rotary furnace operator was exposed to lead at an 8-hour time-weighted average concentration of 280 µg/m3, approximately 5.6 times the permissible exposure limit of 50 µg/m3.   Sampling was performed for 462 minutes during one shift.  Zero exposure was assumed for the unsampled period of 18 minutes.    d) A wastewater treatment equipment operator was exposed  to lead at an 8-hour time-weighted average concentration of 56 µg/m3, approximately 1.1 times the permissible exposure limit of 50 µg/m3.   Sampling was performed for 473 minutes during one shift.  Zero exposure was assumed for the unsampled period of 7 minutes.    e) A kettle operator was exposed to lead at an 8-hour time-weighted average concentration of 840 µg/m3, approximately 16.8 times the permissible exposure limit of 50 µg/m3.   Sampling was performed for 471 minutes during one shift.  Zero exposure was assumed for the unsampled period of 9 minutes.    f) A truck loader was exposed to lead at an 8-hour time-weighted average concentration of 72 µg/m3, approximately 1.4 times the permissible exposure limit of 50 µg/m3.   Sampling was performed for 448 minutes during one shift.  Zero exposure was assumed for the unsampled period of 32 minutes.    Conecsus, LLC was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.1025(e)(1)(i), which was contained in OSHA inspection number 575358, citation number 1, item number 3b and was affirmed as final order on February 5, 2013, with respect to a workplace located at 106 Tejas Drive, Terrell, Texas 75160.
Recent events (2)
  • — I (S) $0
  • — Z (R) $0

View Conecsus, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340028927.