Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: CONECSUS, LLC

Follow-up inspection · Health discipline

On , OSHA opened a follow-up health inspection of CONECSUS, LLC in 106 TEJAS DRIVE, TERRELL, TX 75160 (NAICS 331492). OSHA activity number 343211405.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Conecsus, LLC — free Get an email when a new federal OSHA severe-injury report for Conecsus, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
CONECSUS, LLC
Site address
106 TEJAS DRIVE
City
TERRELL
State
TX
ZIP
75160
Mailing
106 TEJAS DRIVE, TERRELL, TX 75160
Inspection type
Follow-up (F)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
331492
Employees
55
Ownership type
A

3 citations on file for this inspection.

1910.134 F02

Serious Gravity 5 1 instance 1 exposed
Issued
Oct 16, 2018
Abate by
Nov 9, 2018
Penalty
Initial $6,467 · Current $6,467
29 CFR 1910.134(f)(2): Employee(s) using a tight-fitting facepiece respirator were not annually fit tested:  (a) At the vacuum distillation units, an employee who wore a tight-fitting air-purifying respirator did not receive an annual fit test.
Recent events (2)
  • — I (S) $6467
  • — Z (S) $6467

1910.1018 G01 I

Repeat Gravity 10 1 instance 8 exposed
Issued
Oct 16, 2018
Abate by
May 1, 2020
Penalty
Initial $18,108 · Current $18,108
29 CFR 1910.1018(g)(1)(i): Engineering and work practice controls were not instituted to reduce inorganic arsenic exposure to or below the permissible exposure limit:     (a) A kettle operator was exposed to arsenic at an 8-hour time-weighted average concentration of 57 micrograms per cubic meter of air (µg/m3), approximately 5.7 times the permissible exposure limit of 10 µg/m3.  Sampling was performed for 461 minutes during one shift.  Zero exposure was assumed for the unsampled period of 19 minutes.    Conecsus, LLC was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.1018(g)(1)(i), which was contained in OSHA inspection number 1002892, citation number 1, item number 1a and was affirmed as a final order on April 2, 2015, with respect to a workplace located at 106 Tejas Drive, Terrell, TX 75160.
Recent events (2)
  • — I (R) $18108
  • — Z (R) $18108

1910.1025 E01 I

Repeat Gravity 10 5 instances 29 exposed
Issued
Oct 16, 2018
Abate by
May 1, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.1025(e)(1)(i): For any employees exposed to lead above the permissible exposure limit for more than 30 days per year the employer did not implement engineering and work practice controls (including administrative controls) to reduce and maintain employee exposure to lead:    (a) A kettle operator was exposed to lead at an 8-hour time-weighted average concentration of 560 micrograms per cubic meter of air (µg/m3), approximately 11.3 times the permissible exposure limit of 50 µg/m3.  Sampling was performed for 461 minutes during one shift.  Zero exposure was assumed for the unsampled period of 19 minutes.    (b) A rotary furnace operator was exposed to lead at an 8-hour time-weighted average concentration of 150 µg/m3, approximately 3 times the permissible exposure limit of 50 µg/m3.  Sampling was performed for 473 minutes during one shift.  Zero exposure was assumed for the unsampled period of 7 minutes.    (c) A wastewater treatment equipment operator was exposed to lead at an 8-hour time-weighted average concentration of 62 µg/m3, approximately 1.2 times the permissible exposure limit of 50 µg/m3.  Sampling was performed for 474 minutes during one shift.  Zero exposure was assumed for the unsampled period of 6 minutes.    (d) A shipping/receiving worker was exposed to lead at an 8-hour time-weighted average concentration of 86 µg/m3, approximately 1.7 times the permissible exposure limit of 50 µg/m3.  Sampling was performed for 467 minutes during one shift.  Zero exposure was assumed for the unsampled period of 13 minutes.    (e) A maintenance worker was exposed to lead at an 8-hour time-weighted average concentration of 120 µg/m3, approximately 2.3 times the permissible exposure limit of 50 µg/m3.  Sampling was performed for 480 minutes during one shift.    Conecsus, LLC was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.1025(e)(1)(i), which was contained in OSHA inspection number 1002892, citation number 1, item number 1b and was affirmed as a final order on April 2, 2015, with respect to a workplace located at 106 Tejas Drive, Terrell, TX 75160.
Recent events (2)
  • — I (R) $0
  • — Z (R) $0

View Conecsus, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343211405.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.